Diagnostic Error Codes - IBM 8686 - Eserver xSeries 360 Hardware Maintenance Manual

Hardware maintenance manual
Table of Contents

Advertisement

Level 2 light path LED
SP Bus (Remote Supervisor
Adapter)
Non Red (nonredundancy lost)
Out of Spec (power supplies' rating
exceeded)

Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a
Error Code/Symptom
001-198-000 (Test Aborted)
001-XXX-000 (Failed core tests)
001-XXX-001 (Failed core tests)
001-250-00X (Test Failed)
005-XXX-000 (Failed Video test)
011-XXX-000 (Failed COM1 Serial Port
test)
015-XXX-001 (Failed USB test)
015-XXX-015 (Failed USB External
Loopback test)
015-XXX-198 (USB device connected
during USB test)
020-XXX-000 (Failed PCI Interface test)
120
Hardware Maintenance Manual: xSeries 360 Type 8686
FRU/Action
1. See System Error Log
2. Remote Supervisor Adapter card (reseat/replace)
3. System Board
1. If PSX LED is lit on Level 2 light path, follow instructions for that LED.
2. Replace failing power supply
3. Add power supply
Add power supply
FRU. The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
FRU/Action
1. Check error log for messages.
2. Run Quick Memory Test All Banks.
3. Reload system BIOS and rerun test.
System Board
System Board
1. Check error log for messages.
2. Run Quick Memory Test All Banks.
3. Rerun ECC test.
4. Memory board.
5. System board.
1. Video Adapter (if installed)
2. System Board
System Board
System Board
1. Make sure parallel port is not disabled.
2. Re-run USB External Loopback test.
3. System board.
1. Remove USB devices from USB1 and USB2.
2. Re-run test.
3. System Board.
System Board