Using passwords

The System Security choice appears only on the full Configuration/Setup Utility
menu. After you select this choice, you can implement two levels of password
protection: power-on password and administrator password.

Power-on password

After you set a power-on password, you can enable the Unattended Start mode.
This locks the keyboard and mouse but allows the operating system to start. The
keyboard and mouse remain locked until you type the correct password.
You can use any combination of up to seven characters (A–Z, a–z, and 0–9) for
your power-on password. Keep a record of your password in a secure place. When
a power-on password is set, POST is not completed until you type the password. If
you forget the power-on password, you can regain access to the server through one
of the following methods:
v Type the administrator password at the power-on prompt, if an administrator
v Change the position of the power-on password override switch (switch 6 on
v Remove the battery and then reinstall the battery (see the Option Installation

Administrator password

Select this choice to set an administrator password. The administrator password
provides access to all choices on the Configuration/Setup Utility main menu. You
can set, change, or delete both the administrator and power-on passwords and
allow a power-on password to be changed by the user.
For a list of supported options for your server, go to
http://www.ibm.com/us/compat/ on the World Wide Web. To order an optional
Remote Supervisor Adapter, contact your IBM reseller or IBM marketing
representative.
password has been set. (If necessary, see "Administrator password" for details.)
Start the Configuration/Setup Utility program, and change the power-on
password.
switch block 2 on the system board) to bypass the power-on password check.
You can then start the Configuration/Setup Utility program and change the
power-on password. See the Option Installation Guide for an illustration.
Notes:
1. Before changing any switch settings or moving any jumpers, turn off the
server; then, disconnect all power cords and external cables.
2. Any system-board switch or jumper blocks that are not shown in the
illustrations in this book are reserved.
Power-on password override (switch 6 on switch block 2): Changing the
position of this switch bypasses the power-on password check if the switch has
been moved since the server was last turned on. You do not need to move the
switch back to the default position after the password is overridden. The default
position is Off. To bypass the power-on password check, change the position to
On.
Changing the position of this switch does not affect the administrator password
check if an administrator password is set.
Guide).
Chapter 2. Configuring your server