Diagnostic Error Code
086-197-XXX Mouse Port interface test warning
086-198-XXX Mouse Port interface test aborted
086-199-XXX Mouse Port interface test failed, cause
unknown
089-000-XXX Microprocessor Test Passed
089-XXX-XXX Microprocessor failure
089-195-XXX Microprocessor Test aborted by user
089-196-XXX Microprocessor test halt, error threshold
exceeded
089-197-XXX Microprocessor test warning
089-198-XXX Microprocessor test aborted
089-199-XXX Microprocessor test failed, cause unknown
170-000-XXX Voltage Sensor(s) Test Passed
170-0XX-XXX Voltage Sensor(s) failure
170-195-XXX Voltage Sensor(s) Test aborted by user
56
ThinkCentre Hardware Maintenance Manual
FRU/Action
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 37
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 37
2. Flash the system and re-test. See "Flash update
procedures" on page 91
3. Go to "Undetermined problems" on page 63
1. See "Undetermined problems" on page 63
2. Flash the system and re-test. See "Flash update
procedures" on page 91
3. Replace component under function test
No action
1. Microprocessor(s)
2. System board
Information only Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 37
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. Flash the system. See "Flash update procedures"
on page 91
2. Go to "Undetermined problems" on page 63
1. See "Undetermined problems" on page 63
2. Flash the system and re-test. See "Flash update
procedures" on page 91
3. Replace component under function test
No action
1. Flash system
2. System board
Information only Re-start the test, if necessary