OBSERVE
ALL LOCAL CODES AND ORDINANCES,
DO NOT_ UNDER ANY CIRCUMSTANCE& REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
ELECTRICAL GROUND iS REQUIRED ON THIS
APPLIANCE.
For 230/208 volt 60 Hz, AC only, 15A fused and
properly grounded dectrica] supply is required. A time
delay fuse or time delay circuit breaker is
recommended Use a dedicated circuit, sewing only
this appliance_
DO NOT USE AN E_ENSION
CORD.
115V _
230V _
i,
RECOMMENDED GROUNDING M_HOD
For your persona]safety,thisapCance must _ grounded
This app]ian_ has a powersupply cord with a 3-prong
grounding plug. To minimizepossible shock hazard, the
®rd must be pluggedintoa mating groundingtype wall
receptade and grounded in acoord_ce with the National
ElectricalCode (ANS[CNFPA 70} latestedition and all local
codes and ordinals.
If a mating wall receptade is not
available, _ is the personalres_nsibility and obiigalion of
the customerto have a properlygrounded3-prong wali
rece)tade instail_ by a qualifiedd_dciaq.
Power _rd may include a current interrupter
device. A test _d reset button is provided on the
#ug case. The device shodd be tested on a
periodicbasis by first pressingthe TEST button
_d then the RESET button.If the TEST bu_ton
does not
trip or
ifthe RESETbutton will not
stay
engaged,
discontinue use ofthe air conditioner and
contact
a qualified
servicet_hn[cian
NOTE:
The shape may be different
accordhg
to its mo_].
Use
Wall
Receptacle
Power Supply
St_ds_d
125V,
3-wire grounding
receptacle rated
15A, 125V AC
Use 15 AMP time
delay fuse or 15 AMP,
Standard 250V,
citcuil b[eaker,
3-wire grounding
r_placle
ral_]
15A, 250V AC
Standard 250V,
3-wire grounding
Use 20 AMP time
r÷_placle
raled
deiay fuse or 20 AMP,
20A, 250V AC
c _cuit breaker,
Electrical Shock Hazard
Plug into a grounded 3 prong outbt.
Do not remove ground prong
Do not use an adapter,
Do not use an extension cor&
Failure to follow the_
instructions c_
result in
death, fire, or electrical sh_k.
You can choose between
two methods
bdow
according
to your window sill shape and preference.
USING SLIT "A"
Fasten the stopper using 2 screw holes, and lead
out the power _rd through siit "A'_
_f
-4-
USING SLIT "B"
Fasten the stopper using left _rew
hole, and rotate
properly to lead the _wer
cord out through silt "B".