Light Path Diagnostics Panel - IBM 79788BU User Manual

User manual
Hide thumbs Also See for 79788BU:
Table of Contents

Advertisement

v Hard disk drive activity LED: This LED is used on SAS hard disk drives. Each

Light path diagnostics panel

The light path diagnostics panel is on the top of the operator information panel.
To access the light path diagnostics panel, push the release button on the operator
panel to the left. Pull forward on the unit until the hinge of the operator panel is free
of the server chassis. Then pull down on the unit, so that the operator information
panel is at a right angle with the server.
Operator information
panel
The following illustration shows the LEDs and controls on the light path diagnostics
panel.
v Remind button: This button places the system-error LED on the front panel into
v Reset button: Press this button to reset the server and run the power-on
12
IBM System x3550 Type 7978: User's Guide
hot-swap hard disk drive has an activity LED, and when this LED is flashing, it
indicates that the drive is in use.
Release button
Light Path
Diagnostics
OVER SPEC
CPU
REMIND
MEM
SP
FAN
PCI
Remind mode. In Remind mode, the system-error LED flashes rapidly until the
problem is corrected, the system is restarted, or a new problem occurs.
By placing the system-error LED indicator in Remind mode, you acknowledge
that you are aware of the last failure but will not take immediate action to correct
the problem. The remind function is handled by the BMC.
self-test (POST). You might have to use a pen or the end of a straightened paper
clip to press the button. The reset button is to the right of the remind button.
Light path LEDs
PS1
PS2
VRM
CNFG
NMI
S ERR
DASD
RAID
TEMP
BRD

Advertisement

Table of Contents
loading

This manual is also suitable for:

7978b5u7978b9u7978b1u7978bcu7978beuX3550 type 7978

Table of Contents