instant auto-arming bypass
This will bypass the auto arm feature once only.
1.
With the key, turn the ignition on, then off within two seconds.
2.
The siren will chirp once to confirm auto arming bypass.
3.
The system will not auto arm.
n n o o t t e e : : The system will revert to normal auto arming when the system
sees the ignition on for at least three seconds and then turned off, or
the system is armed and disarmed with the remote.
During auto arming bypass the system will not auto-activate the acces-
sory output when using the remote to arm the system.
nuisance prevention
Your system has Directed's Nuisance Prevention
vents annoying repetitive trigger sequences due to faulty switches or
environmental conditions such as thunder, jackhammers, airport noise,
etc.
Example: If the alarm triggers three times within a 60-minute period
and each time the same sensor or switch triggers the alarm, NPC
interpret those triggers as false alarms. After the third trigger, NPC
ignores, or bypasses, that sensor or switch (along with any other sen-
sors or switches sharing the same zone) for 60 minutes.
If the bypassed sensor tries to trigger the system while it is being
bypassed, the 60-minute bypass period will start over. This ensures that
a sensor that continually triggers will remain bypassed.
14
®
circuitry