Turbo Mode - AstroStart RS-623 User Manual

Astrostart remote control engine starter user manual
Hide thumbs Also See for RS-623:
Table of Contents

Advertisement

T
RIGGER INPUT
Your remote starter is equipped with a negative trigger (pulse) input.
This input can be connected to another remote control device or to an AstroStart RTS-2
timer output (optional), part no. 310-903-502.
If this input is connected, consult this device's manual or ask your technician which
command controls the Start/Stop function.
The Start/Stop commands received on this input are ignored while the engine is running on a
remote start.
All Start/Stop functions controlled by this input behave in the same way as functions controlled by remote.
CONTINUOUS MODE
The "Continuous Mode" function allows to remove the key from the ignition while leaving the engine running. This convenient
feature allows you to leave the vehicle for short periods of time while the climate controls remain on.
A
UTOMATIC
TRANSMISSION
VEHICLES
M
ANUAL
TRANSMISSION
VEHICLES
Remove key, exit vehicle and lock doors. All safety devices will remain active.
If you return to your vehicle before runtime has elapsed, just turn the key to the RUN position and depress brake pedal.

TURBO MODE

(Activated at time of installation)
This mode allows the engine to be left running at idle speed for a short period of time so that the turbocharger can cool down
as recommended by certain car manufacturers.
This mode activates the continuous mode at a reduced runtime (one or two minutes according to the programming).
To activate the Turbo Mode, press on the
W
HAT STOPS THE ENGINE
For your safety, engine will not start or will stop if:
ignition switch is in the RUN position (prevents starting);
remote control sends a Stop command;
hood is open;
brakes are applied;
engine is over-revving (programmable during installation);
main switch is OFF;
safety sequence not valid (manual transmission vehicle only - parking brake not applied, opening of door detected
while remote starter was not keeping engine running).
M
AIN SWITCH
The main switch is usually mounted under the dashboard. It is a toggle ON/OFF switch that is
used to cancel start functions.
It does not disable other commands which remain active (lock/unlock commands, etc.).
6
To access Continuous Mode, send start command
while engine is idling (see "START" on page 5).
If Turbo Mode is active, you must press a second time on the
of the remote to set the runtime according to the preset settings.
Parking lights, engine and preset accessories will
remain on for the duration of the programmed runtime.
To access Continuous Mode, send start command before removing the
key from ignition when performing the safety sequence described on page 3.
Note: Do not send the STOP command if you perform
sequence activated by the remote control (Step 6).
If Turbo Mode is on, it will be activated when the safety sequence is executed.
(2 sec.) button (refer to 'Continuous Mode').
See "START" on page 5.
button