MSI K9N2 SLI PLATINUM - Motherboard - ATX User Manual page 101

Ms-7374 (v1.x) mainboard
Table of Contents

Advertisement

Specific M igrating Requirements
The following table lists the disk requirements for a new RAID array for various
migrating combinations.
From
To
RAID 0
RAID 1
RAID 0
RAID 0+1
RAID5
RAID 0
RAID 1
RAID 1
RAID 0+1
RAID 5
RAID 0
RAID 1
RAID 0+1
RAID 0+1
RAID 5
RAID 0
RAID 1
RAID 5
RAID 0+1
RAID 5
Instructions
Click Migrate array to start the Migrate Array W izard and then follow instructions.
You can press F1 to access the online help that walks you through the W izard with
step-by-step instructions.
New Array Disk Requirements
m > n
Number of disks in the new array must be greater than the original array.
m =2, n =1
RAID 1 array must include two disks, converted from a one disk RAID 0
array.
m >= 2 x n
Number of RAID 0+1 disks must be equal to or greater than twice the
number of RAID 0 disks.
m >= n+1
No additional restrictions.
** Not a valid combination **
No additional restrictions.
m >= 3
m >= n2
Number of RAID 0 disks must be equal to or greater than half the number
of RAID 0+1 disks.
** Not a valid combination **
** Not a valid combination **
m >= (n/2 + 1)
m >= n - 1
** Not a valid combination **
m >= 2 x (n -1) ; where m is an even number of disks.
m >= n
nVidia RAID
B-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms-7374

Table of Contents