Desa Vanguard VP1600C Owner's Operation And Installation Manual page 10

Desa owner's operation and installation manual vent-free propane gas heater vp1600c, vp1600it, vp2600c, vp2200it
Table of Contents

Advertisement

INSTALLING
TO WALL
Continued
10
For convenience and efficiency, install heater
• where there is easy access for operation, inspection, and service
• in coldest part of room
An optional fan kit is available from your dealer. See Accessories, page 31 If
planning to use fan, locate heater near an electrical outlet.
8"
Minimum
From
Sides Of
Heater
Left
Side
Figure 4 - Mounting Clearances As Viewed From Front of Heater
THERMOSTAT SENSING BULB
(Models VP1600IT and VP2200IT Only)
The thermostat sensing bulb has been placed inside the heater for protection during
shipping.
Locating Thermostat Sensing Bulb
1. Remove front panel of heater (see Figure 7, page 11).
2. Locate thermostat sensing bulb just under burner assembly.
IMPORTANT:
Attach thermostat sensing bulb to back of heater for proper operation.
Attaching Thermostat Sensing Bulb
1. Remove thermostat sensing bulb from holders inside heater. Route through slot
opening in bottom of heater.
2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided
in hardware package.
3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is
located on lower left edge on back of heater. Make sure the thermostat sensing
bulb is pointing up.
Figure 5 - Attaching Thermostat Sensing Bulb
CEILING
36"
Minimum
Right
Side
3"
Minimum To Top Surface
Of Carpeting, Tile Or Other
FLOOR
Combustible Material
Thermostat
Sensing Bulb
Clamp
100751