OBSERVED PROBLEM
Heater produces unwanted
odors
Heater shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
Log set cycles to pilot, but room
temperature drops to a lower than
ideal level before log set comes
back on
113183-01A
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Heater burning vapors from
paint, hair spray, glues, clean-
ers, chemicals, new carpet,
etc. (See IMPORTANT state-
ment above)
2. Low fuel supply (propane/LP
only)
3. Gas leak. See Warning
statement at top of page
1. Not enough fresh air is avail-
able
2. Low line pressure
3. O D S / p i l o t i s p a r t i a l l y
clogged
1. Gas leak. See Warning
statement at top of page
2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak. See See Warn-
ing statement at top of
page
1. Thermostat sensing bulb
needs to be repositioned
www.desatech.com
REMEDY
1. Open window to ventilate
room. Stop using odor caus-
ing products while heater is
running
2. Refill supply tank (propane/
LP only)
3. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 13)
1. Open window and/or door for
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 19)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 13)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 13)
1. Reposition thermostat sensing
bulb (see Optional Position-
ing of Thermostat Sensing
Bulb, page 24)