INSTALLATION
Continued
THERMOSTAT SENSING
BULB
The thermostat sensing bulb has been
placed inside the heater for protection
during shipping.
Locating Thermostat Sensing
Bulb
1. Remove front panel of heater (see Fig-
ure 2, page 4).
2. Locate thermostat sensing bulb just
under burner assembly.
IMPORTANT: Attach thermostat sensing
bulb to back of heater for proper operation.
Attaching Thermostat Sensing
Bulb
1. Remove thermostat sensing bulb from
holders inside heater. Route through
slot opening in bottom of heater.
2. Place clamp on thermostat sensing bulb
as shown in Figure 11. Clamp is pro-
vided in hardware package.
3. Snap clamp into upper mounting hole
as shown in Figure 11. Mounting hole
is located on lower left edge on back
of heater. Make sure the thermostat
sensing bulb is pointing up.
Figure 11 - Attaching Thermostat Sensing
Bulb
104434

INSTALLATION OPTIONS

There are three options for mounting this
heater.
A. Mounting heater to wall
B. Mounting heater to optional hearth base
C. Mounting heater with optional hearth
base to optional mantel.
A. MOUNTING HEATER TO
WALL
Mounting Bracket
The mounting bracket is located on back
panel of heater. It has been taped there for
shipping. Remove mounting bracket from
back panel.
Figure 12 - Mounting Bracket Location
Methods For Attaching
Mounting Bracket To Wall
Only use last hole on each end of mounting
bracket to attach bracket to wall. These two
holes are 16 inches apart from their centers.
Thermostat
Attach mounting bracket to wall in one of
Sensing Bulb
two ways.
1. Attaching to wall stud
2. Attaching to wall anchor
Attaching to wall stud
vides the strongest hold. Insert mounting
screws through mounting bracket and into
Clamp
wall studs.
Attaching to wall anchor
lows you to attach mounting bracket to
hollow walls (wall areas between studs) or
to solid walls (concrete or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.
OWNER'S MANUAL
Marking Screw Locations
1.
2.
3.
Mounting
Bracket
Figure 13 - Mounting Bracket Clearances
This method pro-
This method al-
9
Tape mounting bracket to wall where
heater will be located. Make sure
mounting bracket is level.
WARNING: Maintain minimum
clearances shown in Figure 13. If
you can, provide greater clear-
ances from floor and joining wall.
Mark screw locations on wall (see Fig-
ure 13).
Note: Only mark last hole on each end
of mounting bracket. Insert mounting
screws through these holes only.
Remove tape and mounting bracket
from wall.
11"
16"
Min.
Only Insert Mounting
Screws Through Last
Hole On Each End
Floor
20 3/4"
Min.
Continued