INSTALLATION
8
Assembling and Attaching Optional Brass Trim

Installation Clearances

INSTALLATION
Continued
ASSEMBLING AND ATTACHING OPTIONAL
BRASS TRIM
(Included with Mantel Accessory)
IMPORTANT: If you are recessing the firebox in a wall, do not
attach brass trim at this time. See page 10.
Note: The instructions below show assembling and attaching brass
trim to fireplace.
1. Remove packaging from three pieces of brass trim.
2. Locate four brass screws, two adjusting plates with set screws,
and two shims in the hardware packet.
3. Align shim under adjusting plate as shown in Figure 6.
4. Slide one end of adjusting plate/shim in slot on mitered edge
of top brass trim (see Figure 6).
5. Slide other end of adjusting plate/shim in slot on mitered edge
of side brass trim (see Figure 6).
6. While firmly holding edges of brass trim together, tighten both
set screws on the adjusting plate with slotted screwdriver.
7. Repeat steps 1 through 6 for other side.
8. Tighten trim hanging screws (#10 x 6.25 shoulder) into holes
in cabinets. Place the assembled trim onto fireplace cabinet.
Align hanging notches on trim with hanging screws on side of
fireplace (see Figure 7). Push trim firmly into place, sliding
hanging notches over hanging screws.
Side Brass
Adjusting
Trim
Plate
Mitered Edge
Slot
Figure 6 - Assembling Brass Trim
Assembled
Brass Trim
Figure 7 - Attaching Brass Trim to Fireplace
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Set Screws
Top
Brass
Trim
Shim
Slot
Trim
Hanging
Screws
Hanging
Notches
on Trim
INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceil-
ing, and adjoining wall.
Carefully follow the instructions below. This will ensure safe
installation.
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace cabinet to any com-
bustible material and wall should follow diagram in Figure 8.
Example: The face of a mantel, bookshelf, etc. is made of
combustible material and protrudes 3
combustible material must be 4" from the side of the fireplace
opening (see Figure 8).
B. Clearances from the top of the fireplace opening to the ceiling
should not be less than 42 inches.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top
Left and
Right Sides
42"
Example
*Minimum 16 inches from Side Wall
Figure 8 - Minimum Clearance for Combustible to Wall
1
/
" from the wall. This
2
Bottom
and Rear
16"
0"
*
111604-01B