Cleaning And Maintenance - Desa EFS10TNA Owner's Operation And Installation Manual

Unvented (vent-free) gas compact classic hearth fireplace
Table of Contents

Advertisement

CLEANING AND
MAINTENANCE
WARNING: Turn off fireplace
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fied service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, bedding material, etc.
WARNING: Failure to keep
the primary air opening(s) of the
burner(s) clean may result in
sooting and property damage.
BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount
of air to mix with the gas. This provides a clean
burning flame. Keep these holes clear of dust, dirt,
lint, and pet hair. Clean these air inlet holes prior to
each heating season. Blocked air holes will create
soot. We recommend that you clean the unit every
three months during operation and have fireplace
inspected yearly by a qualified service person.
We also recommend that you keep the burner tube
and pilot assembly clean and free of dust and dirt.
To clean these parts we recommend using com-
pressed air no greater than 30 PSI. Your local com-
puter store, hardware store, or home center may
carry compressed air in a can. You can use a
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions
on the can. If you don't follow directions on the
can, you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot, and primary air inlet
holes on injector holder for dust and dirt (see
Figure 51).
3. Blow air through the ports/slots and holes in
the burner.
30
4. Check the injector holder located at the end
of the burner tube again. Remove any large
particles of dust, dirt, lint, or pet hair with a
soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the in-
jector holder.
6. In case any large clumps of dust have now been
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
two inches from where the pilot flame comes out
of the pilot assembly (see Figures 52 or 53 depend-
ing on model). With the unit off, lightly blow air
through the air inlet hole. You may blow through a
drinking straw if compressed air is not available.
Ports/Slots
Burner
Tube
Figure 51 - Injector Holder On Outlet
Figure 52 - Pilot Inlet Air Hole
Figure 53 - Pilot Inlet Air Hole
LOG SET
• If you remove one-piece log set for cleaning,
refer to Installing Log Set and Screen, page 23,
for placement instructions.
• Replace log set if broken or chipped (dime-sized
or larger).
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air to clean.
Exterior
• Use a soft cloth dampened with a mild soap and
water mixture. Wipe the cabinet to remove dust.
www.desatech.com
Burner Tube
Pilot Air
Inlet Hole
Pilot Assembly
(Propane/LP Gas)
Pilot Assembly
(Natural Gas)
Injector
Holder
Primary Air
Inlet Holes
Pilot Air
Inlet Hole
112462-01B

Advertisement

Table of Contents
loading