OpERaTING FIREplaCE
Continued
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information on page
26, column 2.
2. Open lower louver panel.
3. Turn off all electric power to the fire-
place.
4. Push in gas control knob slightly and turn
clockwise
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information on page 26, column 2. If
you don't smell gas, go to the next step.
6. The pilot is located by the main burner and
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT (see Figure 51).
8. Push in gas control knob all the way and
hold. Immediately light the pilot by repeat-
edly depressing the piezo spark ignitor until
a flame appears. Continue to hold for about
one (1) minute after the pilot is lit. Release
gas control knob and it will pop back. Pilot
should remain lit. If it goes out, repeat steps
4 through 8.
• If gas control knob does not pop up when
released, stop and immediately call your
service technician or gas supplier.
• If the pilot will not stay lit after several
tries, turn the gas control knob to OFF
and call your service technician or gas
supplier.
9. Turn on all electric power to the fireplace.
10. Turn gas control knob counterclockwise
to ON.
11. This valve is equipped with a HI/LO fea-
ture. Set fireplace input as desired.
12. Close lower louver panel.
Gas Control
Knob
Piezo Ignitor
Figure 51 - Control Valve
116646-01D
to OFF.
Variable Control Knob
www.desatech.com
TO TURN OFF GAS
TO AppLIANCE
1. Open lower louver panel.
2. Set selector switch in the OFF position to
prevent draining battery.
3. Turn off all electrical power to the appliance
if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
5. Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot
lit by doing one of the following:
1. Turn gas control knob clockwise
the PILOT position.
2. Set selector switch in the OFF position.
MANUAL LIGHTING
pROCEDURE
1. Remove glass door (see Removing/Replacing
Glass Door, page 24).
2. Follow steps 1 through 8 under Lighting In-
structions.
3. Depress gas control knob and light pilot
with match.
4. Keep gas control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release gas control knob. Follow steps 10
through 12 under Lighting Instructions.
5. Replace glass door (see Removing/Replacing
Glass Door, page 23).
OpTIONAL HAND-HELD
REMOTE OpERATION
Note: All remote control accessories must be
purchased separately (see Accessories, page 37).
Follow instructions included with the remote
control.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions.
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON posi-
tion. Adjust flame adjustment knob anywhere
between HI and LO. Slide the selector switch
to the REMOTE position (see Figure 52, page
28). Note: The burner may light if hand-held
remote was on when selector switch was last
turned off. You can now turn the burner on and
off with the hand-held remote control unit.
to OFF.
to
7

Advertisement

Table of Contents
loading

Table of Contents