INSTALLATION
Continued
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in cer-
tain areas. Check your local codes. Use pipe of 1/2"
or greater diameter to allow proper gas volume to
fireplace. If pipe is too small, undue loss of volume
will occur.
Installation must include a equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from fireplace (see Figure 21).
IMPORTANT: Install equipment shutoff valve in an accessible
location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.
Check your building codes for special requirements for locating
equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as
shown in Figure 21. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into fireplace controls. If sediment trap is not installed
or is installed wrong, fireplace may not run properly.
Propane/LP
Supply Tank
Figure 20 - External Regulator with Vent Pointing Down
For more information, visit www.desatech.com
For more information, visit www.desatech.com
111410-01C
Figure 21 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer. See Accessories, page 29.
** Minimum inlet pressure for purpose of input adjustment.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not provided)
1.
Route flexible gas line (provided by installer) from equip-
ment shutoff valve into fireplace through side or rear access
holes in outer casing (see Figure 22).
External
Regulator
Vent Pointing
Down
Figure 22 - Routing Flexible Gas Line
Connecting to Gas Supply (Cont.)
Connecting Fireplace to Gas Supply
CSA Design-Certified
Gas Control
Equipment Shutoff Valve With
1/8" NPT Tap*
Approved Flexible
Gas Hose
3" Minimum
INSTALLATION
13
13
Natural Gas
From Gas Meter
(5" W.C.** to 10.5
W.C. Pressure)
Propane/LP
From External
Regulator (11"
W.C.** to 14"
W.C. Pressure)
Cap
Pipe
Tee
Nipple Joint
Sediment Trap
Outer
Casing
Equipment
Shut Off
Valve
To Gas
Supply

Advertisement