Pressure Senders – With Warning Contact, Insulated Return
With Warning Contact, Insulated Return
Technical Data
Rated voltage:
6 V to 24 V
Overpressure safety:
30 bar or 50 bar max.
(short periods only for 2 sec)
Warning contact:
Closes as pressure falls
Switching capacity of
warning contact:
5 W max. non-inductive
Operating temperature:
-25° C to +100° C
(up to +120° C for 1 hour max. at
threaded connector)
Resistance range:
10 Ω to 184 Ω
20
Dimensions
G
Vented
via PTFE
membrane
Type of Connection
A
B
Hex nut (3x)
6.3 x 0.8 mm (3x)
G
M
G
WK
D/E
Special bajonet connector
D/E
1 Sensor
D/E
2 Warning contact
D
3 Ground
3
E
3 Anti-torque guard
1
2
G
Sensor
WK
Warning contact
M
Ground
M4
Thread
ø 46 mm
M
WK
C
6.3 x 0.8 mm (3x)
M
G
M
WK
WK