Replacement Parts; Service Hints; Technical Service; Specifications - Desa Tudor VT36NA Series Owner's Operation And Installation Manual

Desa direct-vent fireplace owner's operation and installation manual (v)t36na, (v)t36pa
Hide thumbs Also See for Tudor VT36NA Series:
Table of Contents

Advertisement

REPLACEMENT PARTS

Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
pARTS UNDER WARRANTY
Contact authorized retailers of this product. If
they can not supply original replacement part(s),
call DESA's Customer Service Department at
1-866-672-6040.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the
factory.
pARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. If they
can not supply original replacement part(s), call
DESA at 1-866-672-6040 for referral information.
When calling DESA, have ready
• model number of your fireplace
• the replacement part number

SERVICE hINTS

When Gas pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (propane/
LP units only)
You may feel your gas pressure is too low. If so,
contact your local gas supplier.

TEChNICAL SERVICE

You may have further questions about installation,
operation, or troubleshooting. If so, contact DESA's
Customer Service Department at 1-866-672-6040.
When calling please have your model and serial
numbers of your heater ready.
You can also visit DESA's technical service web
site at
www.desatech.com
36
.
www.desatech.com

SPECIFICATIONS

(V)T36NA Series and CTDV36NRA
• Rating: 15,400/22,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Minimum Inlet Supply Pressure: 5.5" W.C.
• Dimensions (Actual size of firebox. Measure-
ments do no include nailing flanges or stand-
offs): 36" x 41" x 21
(V)T36PA Series
• Rating: 14,000/20,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10.0" W.C.
• Minimum Inlet Supply Pressure: 11.0" W.C.
• Dimensions (Actual size of firebox. Measure-
ments do no include nailing flanges or stand-
offs): 36" x 41" x 21

ACCESSORIES

NOTICE: All accessories may
not be available for all fireplace
models.
Purchase these fireplace accessories from your
local retailer. If they can not supply these acces-
sories, call DESA at 1-866-672-6040. for informa-
tion. You can also write to the address listed on the
back page of this manual.
BRICK LINER KIT
(Not Shown)
BL36DA - Textured Refractory
BL36DSA - Standard Refractory
BL36DHA - Textured Refractory, Herringbone
BL36DHSA - Standard Refractory, Herringbone
This brick liner adds a touch of style to your direct-
vent fireplace. Complete installation and operation
instructions included in this manual.
FLExIBLE GAS LINE CONNECTOR
GA5081
(Not Shown)
For all models.
pROpANE/NATURAL GAS
CONVERSION KIT
(Not Shown) Included with CTDV36
Model
PCDM-36TA - Propane/LP Gas
NCDM-36TA - Natural Gas
/
"
1
8
/
"
1
8
111250-01E