INSTALLATING OPTIONAL CONTROLS (Cont.)
11
Installing Optional Wireless Remote Control - Model WRC
HIGH ALTITUDE INSTALLATION

GAS SUPPLY AND PIPING

Check Gas Type
Installing Gas Piping to Fireplace
INSTALLING OPTIONAL CONTROLS
Continued
INSTALLING OPTIONAL WIRELESS REMOTE
CONTROL - MODEL WRC (Electronic Ignition)
Installing and Activating the Remote Receiver
1.
Open bottom louver and locate the plug receptacle. The plug
receptacle is located either on the right or left side of cabinet.
2.
The WRC model receiver does not require a battery. The re-
ceiver can be installed by fi rst plugging the short extension
cord into the fi replace receptacle. Then plug the receiver unit
into the extension cord. Finally plug the ignition module plug
into the receiver unit (see Figure 20).
3. Activate the remote handset battery by removing the insulat-
ing tab on the back of the handset (see Figure 21). The battery
is included pre-installed.
4. Once the battery is activated the unit is ready to use.
5. Replace the bottom louver panel.
Fireplace
Receptacle
Extension Cord
Figure 20 - Connecting WRC Remote Control Electronic
Battery Cover
12 Volt Battery
Back of
Handset
Figure 21 - Installing Battery into Back of Handset
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent fi replace has been tested and approved in
the USA for elevations from 0-2000 feet (610 m) and in Canada
at elevations from 0-4500 feet (1372 m).
Remote Control
Receiver
Ignition
Module Plug
Pull to Remove
Insulation Tab
www.desatech.com
When installing a non-high altitude fi replace at an elevation above
2000 feet (610 m) (in the USA), you may need to decrease the input
rating by changing the existing burner orifi ce to a smaller size. Reduce
input 4% for each 1000 feet (305 m) above sea level. Check with
your local gas company for proper derate procedure and orifi ce size.
When installing this fi replace in Canada at an elevation above
4500 feet (1372 m), Check with local or provincial code authorities.
Consult your local gas company to help determine the proper orifi ce
for your location.
For assistance with any high altitude installation contact DESA's
Customer Service Department at 1-866-672-6040.
GAS SUPPLY AND PIPING
CHECK GAS TYPE
Use proper gas type for the fi replace unit you are installing. If your
gas supply is not correct, do not install fi replace. See retailer where
you purchased the fi replace for proper fi replace according to your
gas type or to purchase gas conversion kit (see Accessories, page 33).
INSTALLING GAS PIPING TO FIREPLACE
WARNING: A qualifi ed service person must con-
nect fi replace to gas supply. Follow all local codes.
CAUTION: For propane/LP units, never connect
fi replace directly to the propane/LP supply. This
heater requires an external regulator (not supplied).
Install the external regulator between the fi replace
and propane/LP supply.
External
Regulator
Vent
Pointing
Down
Figure 22 - External Regulator with Vent Pointing Down (Pro-
pane/LP Only)
Propane/LP
Supply Tank
117437-01

Hide quick links:

Advertisement

Table of Contents