Nas Initial Deployment Utility - Dell PowerVault NX3600 Release Note

Powervault fluidfs nas solutions
Hide thumbs Also See for PowerVault NX3600:
Table of Contents

Advertisement

Progress Bar In Microsoft Internet Explorer Version 8 Remains at 99% Completion When Applying Service
Pack Upgrade
Description
When you apply a service pack upgrade using Microsoft Internet Explorer version 8, the
progress bar remains at 99% completion after the service pack is applied successfully.
Workaround/
Follow any of the workarounds to resolve the issue:
Solution

NAS Initial Deployment Utility

Host Discovery Fails For Hosts With More Than One IP/Subnet
Description
Running the NAS IDU on hosts with more than one IP/subnet causes host discovery failures.
Workaround/
Ensure that the system running the NAS IDU is connected to only one subnet.
Solution
Clusterization Fails If Broadcast And Network IP Addresses Are Entered In Host Address Fields
Description
NAS IDU incorrectly accepts broadcast and network IP addresses in host address fields.
Clusterization fails if broadcast or network IP addresses are entered in the host address fields.
Workaround/
Ensure that you do not enter broadcast or network IP addresses in the host address fields.
Solution
Clusterization Fails If There Are IP Address Conflicts
Description
NAS IDU does not check for IP address conflicts on the network. Clusterization fails if IP
address conflicts exist.
Workaround/
After entering all the IP addresses, on the Summary screen, check the list of IP addresses to
Solution
ensure that there are no IP address conflicts with your network environment.
NAS IDU Does Not Automatically Or Manually Discover The NAS Appliance(s)
Description
NAS IDU fails to discover the NAS appliance(s) both automatically and manually.
Workaround/
Connect the system running the NAS IDU to the same switch as the FluidFS NAS appliance(s).
Solution
IP Addresses For Two MD Arrays Required Even When Only When MD Array Is Connected
NOTE: This issue is applicable only to the NX3610 NAS appliance.
Description
The NAS IDU requires IP addresses for two MD arrays even if only one MD array is connected.
Workaround/
You must enter the IP address of the single MD array in both fields.
Solution
Before upgrading the service pack, update the Microsoft Internet Explorer to version 9.
Use any web browser other than Microsoft Internet Explorer version 8 to apply the
service pack upgrade.
Use the Command Line Interface to apply the service pack upgrade.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault nx3610

Table of Contents