7 Select one:
If you are not using CHAP authentication, select No Authentication.
Go to step 8.
or
If you are using CHAP authentication, enter the CHAP user name and
password. To enable Mutual CHAP, select and enter the Mutual
CHAP user name and password.
8 Repeat step 7 for each target until at least one connection is logged in for
each controller.
9 Go to Connected Targets.
10 Verify that the targets are connected and displays a status of true.
Step 7: Connect to the Target Storage Array From
the Host Server
If you are using Windows Server 2008 GUI:
1 Click Start Programs Microsoft iSCSI Initiator or click Start All
Programs Administrative Tools iSCSI Initiator.
2 Click the Targets tab.
If previous target discovery was successful, the iqn of the storage array
should be displayed under Targets.
3 Click Log On.
4 Select Automatically restore this connection when the system boots.
5 Select Enable multi-path.
6 Click Advanced and configure the following settings under the General
tab:
Local Adapter—Must be set to Microsoft iSCSI Initiator.
Source IP—The source IP address of the host server you want to
connect from.
Target Portal—Select the iSCSI port on the storage array controller
that you want to connect to.
Appendix—Manual Configuration of iSCSI
73