Port speed

FCoE Converged Network Switch data flow latency

Table 30
describes the data flow latency for the FCoE Converged Network Switch.
Table 30 Data flow latency for the FCoE Converged Network Switch
Data flow latency type
FC port to FC port
CEE port to CEE port (same ASIC)
CEE port to CEE port (different ASIC)
FCoE to FC

Fibre Channel port specifications

The Fibre Channel ports in the 8-Gb SAN Switch are compatible with SWL, LWL, and ELWL SFP
transceivers. The strength of the signal is determined by the type of transceiver in use.
The ports meet all required safety standards.
The ports are capable of operating at 1, 2, 4, or 8 Gb/s and are able to autonegotiate to the maximum
link speed.

POST and boot specifications

The switch performs POST by default each time it is powered on or rebooted or the system is reset.
Boot time with POST is usually about 1 to 3 minutes.
POST can be skipped after subsequent reboots by entering the fastboot command. For more
information about this command, see the Fabric OS Command Reference Manual.

POST

The success/fail results of the diagnostic tests that run during POST can be monitored through LED
activity, the error log, or the CLI.
POST performs the following tasks:
Conducts preliminary POST diagnostics
Initializes the operating system
Initializes the hardware
Runs diagnostic tests on several functions, including circuitry, port functionality, memory, statistics
counters, and serialization
Cable size
Short wavelength
nl
(microns)
62.5
300 m (984 ft)
9
N/A
Size in nanoseconds
+/– 700 ns
570 ns
1,050 ns
1,670 ns
8-Gb SAN Switch Hardware Reference Guide
Long wavelength
N/A
4 km (2.48 miles)
93