Operating Fireplace - Desa HDCFTN Owner's Operation And Installation Manual

Vent-free compact fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
Equipment Shutoff Valve
Propane/LP
Supply
Tank
Figure 28 - Checking Gas Joints Shown
with Optional Mantel (Propane/LP Gas)
Gas Meter
Figure 29 - Checking Gas Joints Shown
with Optional Mantel (Natural Gas)
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 27,
page 18).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of fireplace is in the
OFF position.
4. Check all joints from equipment shutoff valve
to thermostat gas valve (see Figures 28 and
29). Apply a noncorrosive leak detection fluid
to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light fireplace (see Operating Fireplace).
Check all other internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas to
Appliance, page 20).
8. Replace front panel.