Operating Fireplace - Desa EFS26NRA Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) gas compact classic hearth fireplace vmh26prb, vmh26nrb, efs26nra, efs26pra
Table of Contents

Advertisement

OPERATING FIREPLACE

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don't
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a quali-
fied service technician to inspect the appli-
ance and to replace any part of the control
system and any gas control which has been
under water.
LIGHTING
INSTRUCTIONS
WARNING: You must oper-
ate this fireplace with the fire-
place screen in place. Make sure
fireplace screen is installed be-
fore running fireplace.
22
NOTICE: During initial operation
of new fireplace, burning logs will
give off a paper-burning smell.
Open window to vent smell. This
will only last a few hours.
1. STOP! Read the safety information in col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch in the OFF position.
WARNING: Burner will come
on automatically within one
minute when the selector switch
is in the ON position after the
pilot is lit.
4. Press in and turn control knob clockwise
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information, column 1. If you don't
smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
Press in control knob for five (5) seconds
(see Figure 36).
Note: You may be running this fireplace
for the first time after hooking up to gas
supply. If so, the control knob may need to
be pressed in for 30 seconds or less. This
will allow air to bleed from the gas system.
7. With control knob pressed in, press and re-
lease ignitor button. This will light pilot. The
pilot is attached to the front burner. If needed,
keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 23.
Selector Switch in
OFF Position
Ignitor Button
Figure 36 - Control Knob and Ignitor
Button Location (Shown as Supplied -
www.desatech.com
to the OFF position (see Figure 37).
to the PILOT position.
Control Knob
AUTO
OFF
ON
Flame Adjustment Knob
No Control Options)
113110-01A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Efs26praVmh26nrbVmh26prb

Table of Contents