Coleman CD32M(-1)(-2) Installation Instructions Manual
Coleman CD32M(-1)(-2) Installation Instructions Manual

Coleman CD32M(-1)(-2) Installation Instructions Manual

Direct vent gas fireplace

Advertisement

Quick Links

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will
enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.
This fireplace may be installed as an OEM installation in a manufactured (mobile) home and must be installed in accordance with the
manufacturers instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States or
the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This fireplace is only for use with the type(s) of gas indicated on the
rating plate. A conversion kit is supplied with the fireplace.
WARNING: This Direct Vent gas fireplace is intended for use with natural or propane gas only (depending on the type of gas your
particular model is approved for), do not attempt to burn any solid fuels in this fireplace.
This fireplace is manufactured for Stylecrest Inc. under the Coleman brand name by DESA International Inc.
DESA INTERNATIONAL
2701 INDUSTRIAL DRIVE
P.O. BOX 90024
BOWLING GREEN, KY 42101-9004
www.desatech.com
DIRECT VENT GAS FIREPLACE

INSTALLATION INSTRUCTIONS

SAVE THIS BOOK
CD32M(-1)(-2)
CD36M(-1)(-2)
CD42M
P/N 109194-01
REV D
10/02

Advertisement

Table of Contents
loading

Summary of Contents for Coleman CD32M(-1)(-2)

  • Page 1: Installation Instructions

    WARNING: This Direct Vent gas fireplace is intended for use with natural or propane gas only (depending on the type of gas your particular model is approved for), do not attempt to burn any solid fuels in this fireplace. This fireplace is manufactured for Stylecrest Inc. under the Coleman brand name by DESA International Inc. DESA INTERNATIONAL 2701 INDUSTRIAL DRIVE P.O.
  • Page 2: Table Of Contents

    INTRODUCTION SELECTING LOCATION MINIMUM CLEARANCES VENT PIPE AND TERM. CLEARANCES VENTING INSTRUCTIONS FRAMING GAS SUPPLY TESTING AND HOOK-UP PILOT ADJUSTMENT SPECIFICATION TABLE GLASS PANEL REMOVAL LOG INSTALLATION BURNER FLAME ADJUSTMENT WIRING DIAGRAM LIGHTING INSTRUCTIONS CONVERSION KIT TROUBLESHOOTING ILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS LIST ACCESSORY AND REPLACEMENT PARTS CONTENTS...
  • Page 3: Introduction

    Unless you use DESA/Coleman components, which has been designed and tested for the fireplace system, you may cause a fire hazard. ♦ The DESA/Coleman warranty will be voided by and DESA/Coleman disclaims any responsibility for the following actions: a) Modification of the fireplace, components, doors, blower, fans, air inlet system and damper control.
  • Page 4: Minimum Clearances

    In selecting a location, the following precautions must be observed: Do not connect this appliance to a chimney system used for solid fuel burning fireplace. Due to high temperatures, do not locate this appliance in high traffic areas or near furniture and draperies. Never obstruct the front opening of the appliance or the flow of combustion and ventilation air.
  • Page 5 The final position of your appliance depends on the location of the termination in relation to the clearances that must be observed. A= 12” (305mm) clearance above grade, veranda, porch, deck or balcony. *** B= 9” (229mm) clearance in U.S. and 12” (305mm) clearance in Canada to window or door that may be closed.
  • Page 6: Venting Instructions

    VENT INSTALLATION INSTRUCTIONS 1. Install pipe to fireplace collar adapter located on back of unit at a 45 deg. Angle. Connect our starting pipe to a 45 deg. Starting section by sliding it over the collar adapter on the fireplace. Twist-lock for proper installation check to insure proper connection (see figure 5).
  • Page 7: Framing

    Refer to the following table for clearance between roof and termination. ROOF PITCH MINIMUM HEIGHT ABOVE ROOF FLAT - 7/12 7/12 - 8/12 8/12 - 9/12 9/12 - 10/12 10/12 - 11/12 12/12 - 14/12 14/12 - 16/12 16/12 - 18/12 18/12 - 20/12 20/12 - 21/12 FRAMING...
  • Page 8: Gas Supply Testing And Hook-Up

    The remote control receiver is factory wired and connected to the convertible gas valve as shown in figure 11. Figure 11 REMOTE CONTROL RECEIVER GAS SUPPLY TESTING NOTE: This section is intended as a guide for qualified technicians installing gas to the appliance. WARNING: Do not connect appliance before pressure testing gas piping.
  • Page 9: Pilot Adjustment

    Install a sediment trap between the incoming gas line and the gas control box (see figure 15). The sediment trap should extend down a minimum of 3 inches (76 mm) beyond the center of the pipe. Figure 15 SEDIMENT TRAP When routing gas line through conduit sleeve, make sure to repack insulation to fill gaps between gas line and conduit sleeve.
  • Page 10: Glass Panel Removal

    GLASS PANEL REMOVAL Before proceeding, make sure gas control valve is in the “OFF” position. 1. To remove louvers, pull both spring latches (located in each end of louver) towards center of appliance simultaneously until disengaged from locating holes. Repeat for bottom end spring latches and pull louver outward (see figure 17).
  • Page 11: Burner Flame Adjustment

    • Place log #6 (left log) onto left pin of front log (#2) and the smooth surface of rear log (#3). Make sure it is seated properly. • Place log #7 onto right pin of top log (#5). Make sure it is seated properly.
  • Page 12: Lighting Instructions

    - 11 - For more information, visit www.desatech.com...
  • Page 13: Conversion Kit

    CONVERSION KIT This conversion kit is packaged with the unit. Please check the contents before beginning this conversion. • Before proceeding, make sure the gas control valve is in the “OFF” position and all electrical power to the appliance is turned off. •...
  • Page 14: Conversion Kit

    • Install the identification label enclosed with the gas valve regulator to the valve body where it can easily be seen (see figure 23). Figure 23 GAS CONTROL VALVE CONVERSION WARNING: The conversion kit must be installed by a qualified service technician in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 15: Troubleshooting

    OBSERVED PROBLEM • Pilot will not stay lit after carefully following lighting instructions. • Pilot lit but no flame on the burner. • Frequent pilot outage problem. POSSIBLE CAUSE • Defective pilot generator (thermocouple). • Remote or wires defective. • Thermopile/Thermocouple not generating sufficient millivoltage.
  • Page 16: Illustrated Parts Breakdown

    ILLUSTRATED PARTS BREAKDOWN MODELS CD32M AND CD36M SERIES - 15 - For more information, visit www.desatech.com...
  • Page 17: Illustrated Parts Breakdown

    ILLUSTRATED PARTS BREAKDOWN MODEL CD42M - 16 - For more information, visit www.desatech.com...
  • Page 18: Illustrated Parts List

    ITEM PART # CD32M CD36M 108878-01 108008-01 108874-01 108009-01 108892-01 108010-01 108903-01 108011-01 108903-02 108011-02 108895-01 108015-01 109096-01 108016-01 108896-01 108017-01 108885-01 108074-01 108890-01 108076-01 **11 108897-01 108080-01 **12 108081-01 **13 108901-01 108082-01 **14 108901-02 108083-01 11418 11418 108440-01 12105 108455-02 13113 110037-01...
  • Page 19: Accessory And Replacement Parts

    ACCESSORY AND REPLACEMENT PARTS - 18 - For more information, visit www.desatech.com...