Desa AMITY SDVBPD Owner's Operation And Installation Manual page 14

Cast iron stove and direct-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

VENTING INSTALLATION
14
Installation for Horizontal Termination (Cont.)
VENTING INSTALLATION
Continued
3.
Attach vent pipe assembly to the burner system. Set stove in
front of it's permanent location to insure minimum clearances.
Mark the wall for a 10"(25.4cm) square hole (for noncombus-
tible material such as masonry block or concrete, a 7
diameter hole is acceptable). See Figure 24. The center of the
hole should line up with the center-line of the horizontal rigid
vent pipe. Cut a 10"x10" (25.4cm x 25.4cm) square hole through
combustible exterior wall (7
noncombustible). Frame as necessary (see Figure 24).
4.
Noncombustible Exterior Wall:
ing mastic around the outside edge of the vent cap. Position the
vent cap in the center of the 7
wall with the arrow on the vent cap pointing up. Attach the vent
cap with four wood screws provided (see Figure 25). Note : Re-
place the wood screws with appropriate fasteners for stucco, brick,
concrete, or other types of siding.
WARNING: Do not recess vent termination in to
any wall. This will cause a fire hazard.
Combustible Exterior Wall:
exteriors, a siding standoff must be installed between the vent
cap and exterior wall. The siding standoff prevents excessive
heat from damaging siding materials. Siding materials must be
cut to accommodate standoff. Bolt the vent cap to the stand-
off. Apply non-hardening mastic around outside edge of the
standoff. Position the standoff/cap assembly in the center of
the 10" (25.4cm) square hole and attach to exterior wall with
wood screws provided (see Figure 26). The siding standoff must
sit flush against the exterior fascia material.
5.
Combustible Exterior Wall Only:
firestop over the vent pipe before connecting the horizontal
run to the vent cap (see Figure 27).
Figure 24 - Vent Opening Requirements
For more information, visit www.desatech.com
For more information, visit www.desatech.com
1
/
" (19.1cm)
2
1
/
" [19.1cm] diameter hole if
2
Apply a bead of non-harden-
1
/
" (19.1cm) hole on the exterior
2
For vinyl siding, stucco, or wood
Slide the interior wall
6.
Carefully move the fireplace with vent assembly attached toward
the wall and insert the vent pipe into the horizontal termination.
The pipe overlap should be a minimum of 1
all vent pipe connections (except vent cap) with screws provided.
7.
Combustible Exterior Wall Only:
against the interior wall surface and attach with screws pro-
vided (see Figure 27).
Figure 25 - Installing Horizontal Vent Cap (Noncombustible
Exterior)
Apply Mastic
to All Four Sides
Figure 26 - Installing Vinyl Siding Standoff (Combustible Exterior
Wall)
Vent Cap
(Horizontal
Termination)
Figure 27 - Connecting Vent Cap with Horizontal Vent Pipe
1
/
" (3.2cm). Fasten
4
Slide the wall firestop
Vent Cap
Wood Screw
Cut Vinyl Siding
Away to Fit Standoff
Standoff
Wood Screw
Vent Cap
Bolt
Interior Wall
Surface
Interior Wall Firestop
(Combustible
Exterior Wall Only)
Horizontal
Vent Pipe
Screw
112126-01B

Advertisement

Table of Contents
loading