Replacement Parts; Specifications; Service Hints; Technical Service - Desa VKC36N Series Owner's Operation And Installation Manual

Direct-vent fireplace
Table of Contents

Advertisement

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized retailers of this product. If they can not supply
original replacement part(s), call DESAʼs Customer Service Depart-
ment at 1-866-672-6040.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. If they can not supply
original replacement part(s), call DESA at 1-866-672-6040 for
referral information.
When calling DESA, have ready
• model number of your fireplace
• the replacement part number

SPECIFICATIONS

Btu
Gas Type
Ignition
Manifold Pressure
Minimum Inlet
Supply Pressure
Dimension (H x W x D) Fireplace
(Actual size of firebox.
Measurements do not include
nailing flanges or standoffs).
Carton
Weight, lbs/kg*
Fireplace
Shipping
116226-01A
23,000/33,000 Btu/hr
22,000/31,000 Btu/hr
Natural
Piezo
3.5" w.c.
5.5" w.c.
36" x 41" x 21
/
"
1
8
914 x 1041 x 537 mm
914 x 1041 x 537 mm
38" x 44" x 22"
965 x 1118 x 559 mm
965 x 1118 x 559 mm
165 lbs/75 kg
168 lbs/76 kg
www.desatech.com

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local
gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation or
troubleshooting. If so, contact DESAʼs Customer Service Depart-
ment at 1-866-672-6040. When calling, please have your model
and serial numbers of your heater ready.
You can also visit DESAʼs technical service web site at
.
www.desatech.com
Propane/LP
Piezo
10.0" w.c.
11.0" w.c.
36" x 41" x 21
/
"
1
8
38" x 44" x 22"
165 lbs/75 kg
168 lbs/76 kg
REPLACEMENT PARTS
SPECIFICATIONS
SERVICE HINTS
TECHNICAL SERVICE
31
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vkc36p seriesKc36n seriesKc36p series

Table of Contents