Installation (continued)
4.
Camera body
cover
Camera body
cover
Setting
switches
5.
SW1
1
2
Board
CAUTION
The setting of these switches will be read only once at the
time when the power is turned on. Even if the setting is
changed in a state where the power is on, such a change
will not be reflected.
5.
6
RELEASE
LOCK
Mark
Transportation bracket
Reserved
SW2
This switch must be set OFF.
DISP
SW3
PROTOCOL (1)
SW4
PROTOCOL (2)
SW5
SYNC
SW6
DOUBLE
SINGLE
FIGURES
FIGURES
0
3
4
5
6
Machine ID
TERM switch
4.
Turn the camera body cover to anti clockwise to set the word
"RELEASE" on the camera body cover over the mark, then pull
the camera body cover upward.
Transportation bracket is mounted when it is shipped from the
factory. Make sure to remove it before installation.
<How to remove the transportation bracket>
1
Remove the screw to remove the transportation bracket.
2
Then fasten the dome cover with the screw which was removed.
CAUTION
If the power is supplied without removing the transportation
bracket, initialization won't be carried out properly, so that the
camera cannot be controlled with a remote control unit.
Make sure that it is removed.
5.
Check the switch settings and the communication protocol.
Read the controller specifications carefully before proceeding
to the switch settings.
Switch settings
DISP , PROTOCOL (1), (2), SYNC, Machine ID. Set these switch-
es as required.
DISP (SW3)
Selects whether "MANUAL" is displayed or not when the cam-
era's preset position is changed by the manual operation of the
remote control unit.
MANUAL
Displayed
Not displayed
PROTOCOL (1) (SW4)
Selects whether a single or multiple cameras are controlled in
the system.
Set PROTOCOL(1) to Multi drop when connecting multiple cam-
eras in series.
PROTOCOL (1)
Point to point
Multi drop (when using the RM-P2580)
When set to Multi drop, be sure to set the Machine ID of each camera.
PROTOCOL (2) (SW5)
0
Set according to the communication protocol used for control-
ling the cameras.
PROTOCOL (2)
Duplex (when using the RM-P2580)
Simplex
Ref. "Control signal connection" is on page 9.
SYNC (SW6)
When this switch is set to ON, the vertical sync of the camera is
locked to the AC power line frequency.
SYNC
INT
LL
• SW1 and SW2 are not in use for the present. Make sure that
they are set to OFF.
Machine ID
0
TERM switch
• When SW4 is set to ON in order to connect more
ON
OFF
RX TERM
(110 )
SC46125-002
(Initial set: ON)
• When SW4 is set to OFF, this switch should be set to
SW3
OFF
ON
(Initial set: OFF)
SW4
OFF
ON
SW5
OFF
ON
LL mode
SW6
OFF
U type: 60 Hz area only
ON
E type: 50 Hz area only
(Initial set: OFF)
The machine ID should be set when us-
0
ing the camera in Multi drop.
Choose an ID in the 1 to 32 range.
(Initial set: 00)
than one camera in series, set the TERM switch of
only the terminal camera to ON. The TERM switch-
es of the other cameras should be set to OFF.
See "Connections" on page 8.
ON.
(Initial set: OFF)
(Initial set: OFF)