Troubleshooting; For More Information, Visit Www.desatech.com For More Information, Visit Www.desatech.com - Desa VP10A VN10TA Owner's Operation And Installation Manual

Vent-free gas heater
Table of Contents

Advertisement

TROUBLESHOOTING

16
TROUBLESHOOTING
Note: For additional help, visit DESA
International's technical service web site
at www.desatech.com.
Note: All troubleshooting items are listed in
order of operation.
OBSERVED PROBLEM
When ignitor button is pressed, there is no
spark at ODS/pilot
When ignitor button is pressed, there is
spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when
control knob is released
WARNING: Turn off heater
and let cool before servicing. Only
a qualified service person should
service and repair heater.
POSSIBLE CAUSE
1. Ignitor electrode positioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not connected to igni-
tor cable
4. Ignitor cable pinched or wet
5. Piezo ignitor nut is loose
6. Broken ignitor cable
7. Bad piezo ignitor
1. Gas supply turned off or equipment
shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
4. Air in gas lines when installed
5. Depleted gas supply (propane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not correct
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Equipment shutoff valve not fully open
4. Thermocouple connection loose at con-
trol valve
5. Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
For more information, visit www.desatech.com
For more information, visit www.desatech.com
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.
REMEDY
1. Replace pilot assembly
2. Replace pilot assembly
3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
5. Tighten nut holding piezo ignitor to
heater cabinet. Nut is located inside
heater cabinet at top
6. Replace ignitor cable
7. Replace piezo ignitor
1. Turn on gas supply or open equipment
shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Continue holding down control knob.
Repeat igniting operation until air is re-
moved
5. Contact local propane/LP gas company
6. Clean ODS/pilot (see Cleaning and
Maintenance, page 15) or replace ODS/
pilot assembly
7. Replace gas regulator
1. Press in control knob fully
2. After ODS/pilot lights, keep control
knob pressed in 30 seconds
3. Fully open equipment shutoff valve
4. Hand tighten until snug, then tighten 1/4
turn more
5. A) Contact local natural or propane/LP
gas company
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 15) or replace ODS/
pilot assembly
6. Replace pilot assembly
7. Replace control valve
110720-01B