Product Identification; Local Codes; Product Features; Safety Device - FMI VFN24MV VFN30MV Owner's Operation And Installation Manual

Unvented (vent-free) natural gas log heater
Hide thumbs Also See for VFN24MV VFN30MV:
Table of Contents

Advertisement

SAFETY
INFORMATION
Continued
13. Do not operate heater if any log is bro-
ken. Do not operate heater if a log is
chipped (dime-sized or larger).
14. Turn heater off and let cool before ser-
vicing. Only a qualified service person
should service and repair heater.
15. Operating heater above elevations of
4,500 feet may cause pilot outage.
PRODUCT
IDENTIFICATION
Top Middle Log
Left Front Log
Piezo
Ignitor
Front
Burner
Base Assembly
Control Knob
Figure 1 - Ember Master
105070

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Crossover Log
Rear Log
Right Front Log
3
OWNERS MANUAL
UNPACKING
metal data plates attached to the
heater base assembly. The data
plates contain important warranty
information.
1.
Remove logs and heater base assem-
bly from carton. Note: Do not pick up
heater base assembly by burners. This
could damage heater. Always handle
base assembly by grate.
2. Remove all protective packaging ap-
plied to logs and heater for shipment.
3. Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.
PRODUCT
FEATURES
OPERATION
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
both realistic flames and glowing coals.
This heater is designed for vent-free opera-
tion with flue damper closed. It has been
tested and approved to ANS Z21.11.2 stan-
Rear
Burner
dard for unvented heaters. State and local
codes in some areas prohibit the use of vent-
free heaters. This heater may also be oper-
ated as a vented decorative (ANS Z21.60)
product by opening the flue damper.

SAFETY DEVICE

Bottom
Middle Log
This heater has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
shuts off the heater if there is not enough
fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
CAUTION: Do not remove the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vfn30mvVfn18mv

Table of Contents