3. Locate ignition hole in underside of burner
(see Figure 3). Hold a lit match under ignition
hole. Push in the safety shutoff valve plunger
(see Figure 3). Burner should light. Mesh
screen on burner glows red when lit. After
burner is lit, continue holding in safety shutoff
valve plunger for 10 to 30 seconds until heater
stays lit.
4. If the burner does not light within 30 seconds,
turn the regulator knob to the "OFF" position.
Wait at least two minutes for the gas to dis-
sipate before relighting.
5. If heater will not light after repeated tries,
do not attempt to repair heater. Return heater
to nearest authorized service center or to
address on back page of this manual, freight
prepaid.
6. After heater stays lit, turn the heater regulator
knob to the desired heat setting (LOW, MED,
or HI).
Air Inlet
Hole
Safety
Shutoff Valve
Plunger
Figure 3
4
Ignition
Hole
www.desatech.com