Firewerks SBJ18VNA Owner's Operation And Installation Manual page 10

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

INSTALLATION
Continued
Example
*Minimum 16 inches from Side Wall
Figure 4 - Minimum Clearance for
Combustible to Wall
NOTICE: Non thermostat con-
trolled heaters may be used as
a vented product. If so, you must
always run heater with chimney
flue damper open and damper
clamp installed. If running heater
with damper open, noncombus-
tible material above the fireplace
opening is not needed. Go to
Installing Damper Clamp Ac-
cessory for Vented Operation,
page 12.
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel proceed to If Using Man-
tel. If not using mantel, follow the information
on this page.
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materi-
als (such as slate, marble, tile, etc..) Must be at
least 1/2" thick. With sheet metal, you must have
noncombustible material behind it. Noncombus-
tible material must extend at least 8" up (for all
models). If noncombustible material is less than
12", you must install the fireplace hood accessory
(24" Models Only). See Figure 5 for minimum
clearances.
10
Noncombustible
Material Distance (A) Safe Installation
12" or more
Between 8" and 12"
*
Less than 8"
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
If Using Mantel
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2" thick. With sheet metal, you must have non-
combustible material behind it. Noncombustible
material must extend at least 8" up (for all models).
If noncombustible material is less than 12", you
must install the fireplace hood accessory (24"
Models Only). Even if noncombustible material
is more than 12", you may need the hood acces-
sory to deflect heat away from your mantel shelf.
See Figure 5 and Figures 6 and 7, page 11, for
minimum clearances.
IMPORTANT: If you cannot meet these minimum
clearances, you must operate heater with chimney
flue damper open. Go to Installing Damper Clamp
Accessory for Vented Operation, page 12.
www.desatech.com
Requirements for
Noncombustible
material OK.
24" Models:
Install fireplace hood
accessory (GA6050,
GA6052, GA6053, see
Accessories, page 27).
18" Model: Noncom-
bustible material OK.
Noncombustible
material must be
extended to at least
8". See Between 8"
and 12", above. If you
cannot extend material,
you must operate
heater with flue damper
open and damper
clamp installed.
Heat Resistant
Material
(A)
114744-01C