5.1 Preparation of Manual Alignment

1.1 The alignment procedure is performed after unit has been completely
assembled and before set inspection.
1.2 Before Alignment, set should be burned-in for over 30min.
1.3 measuring equipment used
Pre-programmed chroma 2226 or equivalent products.
Color meter-- Minolta CA210 or equivalent products.
1.4 methods to enter/exit factory mode
1.4.1 Press "2" and "down" key and power on to set the monitor to the burn-in mode.
1.4.2 Press "VOL-" and "1" key and power on to set the monitor to the factory mode.
1.4.3 To ensure the monitor is under factory mode, check the status in the OSD
menu screen.
VX800-3
Color Temp
Factory Default
Brightness
Blacklevel
AutoColor
Initial
EDID
CopyColorTemp
Gamma
Otherwise, follow the procedure
described in session 1.4.1 to enter the factory mode again