Advertisement

4 The compressor doesn't work
The compressor doesn't
work.
Does the refrigerated
room lamp illuminate
when the door is
opened?
YES
Is the ambient
temperature low than
16℃
Does the control
panel has 220V power
output?
YES
Does the compressor
has 220V power
output?
YES
Check and repair
compressor and accessory.
Maintenance Service and Trouble Shooting
Check the power
NO
source and power
cord?
YES
YES
Check the therostat is
correct?
NO
Check and repair the
control panel.
NO
Check all cords and
power cords.
15
NO
Repair
Adjust and instruct
consumer how to use.

Advertisement