Haier 102102429 Service Manual

User manual

Advertisement

Service Manual
.................
Features
Energy efficiency
Micro foam technology
Low noise operation
Thick insulation for energy efficiency
Serial number: ER03SM0120-17
102102429 (HF-240TA)
FREEZER
Haier Group
0
Models:
HF-120T
HF-120TA
HF-180T
HF-180TA
HF-240T
HF-240TA
Version number: 00.00
Edition: 2003-01-20

Advertisement

Table of Contents
loading

Summary of Contents for Haier 102102429

  • Page 1 102102429 (HF-240TA) FREEZER Service Manual …………….. Models: HF-120T HF-120TA HF-180T HF-180TA HF-240T HF-240TA Features Energy efficiency Micro foam technology Low noise operation Thick insulation for energy efficiency Haier Group Serial number: ER03SM0120-17 Version number: 00.00 Edition: 2003-01-20...
  • Page 2: Table Of Contents

    CONTENT CONTENT 1. C o n t e n t … … … … … … … … … … … … … … … … … … … … . 2. Product code illumination and Series Introduction…… 2 3. Specifications……………………….……..……………………. 3 4.
  • Page 3: Product Code Illumination And Series Introduction

    Product code illumination and Series Introduction Product code illumination and Series Introduction H F — 240 TA (102102429) Serial Number Gross capacity (according to export country standard) Freezer Haier product...
  • Page 4: Specifications

    Specifications Specifications HF-120T HF-180T HF-240T Models HF-120TA HF-180TA HF-240TA Net capacity Color White White White Power Supply 220-240~/50 220-240~/50 220-240~/50 (V/Hz) Rated Input Power Power Consumption 0.60 0.63 0.67 (kW.·h/24h) Net Weight (kg) Gross Weight (kg) Unit Dimension (D*W*H) 600x600x850 600x600x1134 600x600x1467 (mm)
  • Page 5: Safety Precautions

    Safety precautions Safety precautions...
  • Page 6 Safety precautions...
  • Page 7 Safety precautions...
  • Page 8: Parts And Functions

    Parts and Functions Parts and Functions A Foamed Cabinet B Short Drawer C Long Drawer D Lower Plate E Control Panel F Foamed Door...
  • Page 9: Function Schedule

    Function Schedule Function Schedule Energy efficiency Micro foam technology Low noise operation Thick insulation for energy efficiency...
  • Page 10: System Flow Chart

    System Flow Chart System Flow Chart 1 Schematic diagram of System Flow Char 2 Brief Description of System Flow Chart HF-120T/180T/240T is a direct cooling single-system freezer. When the freezer is just powered on, the refrigerant flows in the sequence: 1->2->3->4->5.
  • Page 11: Circuit Diagram

    Circuit Diagram Circuit Diagram Schematic Circuit Diagram A STECKER B GEFRIERSENSOR C RAUMSENSOR D SCHALTTAFEL E ÜBERBELASTUNGS- SCHUTZAPPARAT F KOMPRESSOR G PTC H LAUFENDE KAPAZITANZ Brief Description of Control Principle...
  • Page 12: Maintenance Service And Trouble Shooting

    Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting 1 No cooling No cooling If compressor Check and repair according to can run after it stop to the section of "the compessor run five minutes and doesn't work". give power. If compressor Refrigerant can run naturally and...
  • Page 13: Maintenance Service And Trouble Shooting

    Maintenance Service and Trouble Shooting 2 The compressor doesn’t stop Comprossor doesn't stop Check and repair according to Does the refrigerator the section of "No cooling". refrgerate? Check and repair according to Is cooling capacity the section of "Cooling capacity insufficient.
  • Page 14 Maintenance Service and Trouble Shooting 3 Cooling capacity is insufficient Cooling capacity is insufficient Is the ambient Check the therostat is temperature low than correct? 16℃ Does the refrigerant Adjust and instruct leak siowly?. consumer how to use. Repair...
  • Page 15 Maintenance Service and Trouble Shooting 4 The compressor doesn’t work The compressor doesn't work. Does the refrigerated Check the power room lamp illuminate Repair source and power when the door is cord? opened? Is the ambient Check the therostat is temperature low than correct? 16℃...
  • Page 16 Maintenance Service and Trouble Shooting 5 Normal Phenomena—Not Troubles for Refrigerators In a domestic refrigerator, there is not only a complicated electric control system, but also a refrigerating system that is difficult to discern whether it is in a good working condition. Both the systems are related and affect each other.
  • Page 17 Maintenance Service and Trouble Shooting 6 Common Troubles in Refrigerators and Their Remedies Causes for troubles occurring in refrigerators are closely related to the quality of components and workmanship in assembling by manufacturers as whether refrigerators are properly used and maintained .The parameters generally used to express the working conditions of a refrigerator include the temperature inside the refrigerator ,operation rate ,electric power consumption ,noise level ,and other functional indexes .If any one of these...
  • Page 18 Maintenance Service and Trouble Shooting Hums from a fully enclosed aggregate unit is the sound caused by overload indicating that the motor cannot be started normally ,meanwhile ,a clattering sound can be heard from inside the start relay ,which is produced because the start contacts cannot be released normally .A whistling sound is caused by the high pressure gas flowing out of the crack of the pressure tube inside the compressor ,and clucks are the sound of striking after the...
  • Page 19 Maintenance Service and Trouble Shooting ambient temperature ,this means that most meshes of its screen has been clogged ,resulting in an obstructed flowing of refrigerant ,thus causing a drop in temperature due to throttling . Feel the temperature of exhaust gas from the refrigerating system .the exhaust gas should be very hot and this is the normal working state .For those refrigerator with enclosed type of compressor refrigerating system, no frost or dew drop will from on the gas suction...
  • Page 20 Maintenance Service and Trouble Shooting There many joints sealed surfaces refrigerator ,accordingly ,quite a lot potential leak points do exist in the system .In troubleshooting ,pay attention to those parts that are liable to leak ,check main connection points for oil seepage and tubing for cracks .If there is no severer leak point ,charge the system with nitrogen and detect leak points...
  • Page 21 Maintenance Service and Trouble Shooting Analysis of Trouble Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharge capacity ,and hence the corresponding reduction of refrigerating capacity ,under the condition that the refrigerant in the system is unchanged .This phenomenon occurs mostly when the compressor has been used for quite a long time ,its moving parts have worn to a considerable degree ,fit clearance between various parts have increased and sealing property of its gas valve has deteriorated ,resulting...
  • Page 22 Maintenance Service and Trouble Shooting refrigerating effect is due to the accumulation of refrigerating oil left in the evaporator tubing in case no other troubles have been found . To clear off refrigerating oil left in the evaporator ,dismantle the evaporator ,purge it thoroughly and then dry it .In case it is difficult to dismantle it ,charge refrigerant from the evaporator inlet to wash it several times ,then purge and dry it with nitrogen .
  • Page 23 Maintenance Service and Trouble Shooting heard ,and no will gush out of the process tube if you cut it open after shutdown . Remedy Check the whole machine , particularly those locations which are liable to leak .After leak points have been found ,repair them or replace them with new parts according to specific circumstances ,then evacuate the system and finally charge refrigerant.
  • Page 24 Maintenance Service and Trouble Shooting caused by dirt , tapping the suspicious clogged point (generally in the capillary or the connection joint of the filter) may cause the refrigerant to flow through partially, resulting in some corresponding change, whereas in that case if you heat it with a hot towel, no reaction will happen, no flowing sound can be heard, moreover, there is no periodic change.
  • Page 25 Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting The cause of sudden stop of a compressor during its running is mostly that the gas suction pressure and/or discharge pressure exceed their respective prescribed ranges, thus making a pressure-operated protective relay shut off the power to the compressor and stop it.
  • Page 26 Maintenance Service and Trouble Shooting temperature sensor has not been installed properly, frequent stoppage is also likely to occur. Remedy Try to adjust the temperature sensor’s position until the compressor can be started and stopped normally. If this cannot be achieved, and the stoppage still occurs repeatedly, it is most likely that the mechanical parts or contacts are out of order, disassemble the thermostat, make a thorough checkup and repair it.
  • Page 27 Maintenance Service and Trouble Shooting a) Check the input power circuit to see whether where is voltage of the power supply, namely, the circuit which is connected to the knife switch. This can be determined with an avometer or a test pencil. If a blown fuse is found, ascertain and remove its cause, then replace it with a new one of the same specifications.
  • Page 28 Maintenance Service and Trouble Shooting avometer. If short circuit occurs or the resistance of a certain phase is low, this means that short circuit does exist in the windings and/or between turns, and insulation layers have been burned or deteriorated. A megameter can be used in this inspection, too.
  • Page 29 Maintenance Service and Trouble Shooting position is to be used for fast freezing or continuous running, its temperature for power off is too low, therefore, the compressor won’t stop and the temperature in the refrigerator becomes lower and lower . b) Inspection method: check the temperature control knob to see whether it is set in the position “coldest”.
  • Page 30 Maintenance Service and Trouble Shooting dissipation make the compressor running without stop. F. Electric leakage of refrigerator 1) Slight electric leakage Electric insulation has deteriorated due to being affected with damp, thus resulting in slight electric leakage. 2) Serious electric leakage Refrigerator case has become live due to faults occurred in some electric devices or the erroneous wiring in installing power cord plug or outlet by the user.
  • Page 31 Maintenance Service and Trouble Shooting 4) Inspection method To find the sources of noise ,press the vibration spot with your hand while the refrigerator is in operation and listen attentively whether the vibration becomes weaker or vanishes .If the refrigerator has not been levelly placed ,put a level meter on its top table and adjust the leveling screws on its legs .In case noise occurs from the compressor ,strike different locations on the side surface of its case using a rubber hammer or...
  • Page 32: Exploded View

    Exploded View...
  • Page 33: List Of Parts

    List of Parts Refrigerator Model: 102102429 Product code: 10602291100 related No. In the technical Spare parts proportion exploded Spare parts description in English Model Qty Failure rate Remark bulletin number of the spare view part stock number 0060200760 Short drawer 102102429 0.14%...
  • Page 34 0.00% 0.00% 0067402605 Hinge screw hole cover 102102429 0.00% 0.00% 0067412329 Temperature display panel 102102429 0.00% 0.00% 0067203070 Sensor temperature tube spring clip 102102429 0.00% 0.00% 0069301020 Sensor temperature tube seat 102102429 0.00% 0.00% 0064240002 Spring washer 102102429 0.00% 0.00%...