Desa HRB3624 Owner's Operation And Installation Manual page 11

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

INSTALLATION
Continued
NOTICE: Surface temperatures
of adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch.
If installed properly, these tem-
peratures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
10"
8"
6"
2
1 /2
Minimum Non-
Combustible
Material
Minimum Non-
Combustible
Material Height
Figure 6 - Minimum Mantel Clearances
Without Using Hood
119426-01A
Mantel Shelf
Underside of
Mantel Shelf
"
All minimum
distances are
in inches
(A)
12"
18"
20"
22"
24"
8"
14"
17"
19"
20"
Top of
Fireplace
Opening
Distances to
Underside of
Mantel
www.desatech.com
Minimum
Noncombustible
Material
Figure 7 - Minimum Mantel Clearances
FLOOR CLEARANCES
A. If installing appliance on the floor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 8).
B. If combustible materials are less than 14" to
the fireplace, you must install appliance at
least 5" above the combustible flooring (see
Figure 9).
Log Set
24"/30"/36"
Figure 8 - Minimum Fireplace Clearances
Models
18" Model
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Mantel Shelf
12"
10"
8"
6"
2
1 /2
"
8"
12"
15"
Min.
Hood
Distances to
(GA6050,
Underside of
GA6052,
Mantel
or GA6053)
When Using Hood
14"
Min.
Noncombustible Material
If Installed at Floor Level
Hearth
Underside of
Mantel Shelf
All minimum
distances are
in inches
Log Sets
18"
20"
18", 24",
& 30"
Models
Top of
Fireplace
Opening
Combustible
Material
Combustible
Material
5"
Min.
11