Operating Heater - Desa GN30T Safety Information And Installation Manual

Unvented (vent-free) blue flame gas heater
Table of Contents

Advertisement

OPERATING HEATER

MANUAL CONTROL MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don't
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is
fully open.
3. Press in and turn control knob clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas around heater and near
the floor. If you smell gas, STOP! Follow
"B" in the safety information above. If you
don't smell gas, go to the next step.
107884-01H
5. Press in control knob and turn counter-
clockwise
Keep control knob pressed in for five (5)
seconds (see Figure 19).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
• If control knob does not pop up when re-
leased, contact a qualified service person
or gas supplier for repairs.
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the front of
burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 20 through 23. Also
contact a qualified service person or gas
supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with
match, see Manual Lighting Procedure,
page 16.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7.
8. Press in and turn control knob counter-
clockwise
control knob to desired heat setting.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Ignitor
Button
Figure 19 - Control Knob In The OFF
Figure 20 - Pilot (actual pilot may vary)
www.desatech.com
to the PILOT position.
to the HIGH position. Set
OFF
IGNITOR
Position
Thermocouple
Ignitor Electrode
Pilot Burner
Control
Knob
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents