Inspecting Burner; Cleaning And Maintenance; Pilot Flame Pattern; Burner Flame Pattern - Desa Comfort Glow CGN10TA Owner's Operation And Installation Manual

Desa owner's operation and installation manual vent-free natural gas heater cgn10ta, cgn10tla
Table of Contents

Advertisement

VENT-FREE NATURAL GAS HEATER
INSPECTING
BURNER
Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pat-
tern. Figure 18 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.
If pilot flame pattern is incorrect, as shown
in Figure 18
• turn heater off (see To Turn Off Gas to
Appliance, page 11)
• see Troubleshooting, pages 13 through 15
Pilot Burner
Thermocouple
GOOD PILOT
Figure 17 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
BAD PILOT/LP
Figure 18 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 19 shows a correct burner flame
pattern. Figure 20 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pattern
shows yellow tipping, follow in-
structions at bottom of this page.
CGN10TA and CGN10TLA
NOTICE: Do not mistake orange
flames with yellow tipping. Dust
or other fine particles enter the
heater and burn causing brief
patches of orange flame.
If burner flame pattern is incorrect, as shown
in Figure 20
• turn heater off (see To Turn Off Gas to
Appliance, page 11)
• see Troubleshooting, pages 13 through 15
Figure 19 - Correct Burner Flame Pattern
Figure 20 - Incorrect Burner Flame Pattern
GRH/OV 009
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
GRH/OV 008
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.
ODS/PILOT AND BURNER
ORIFICE
• Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CLEANING BURNER
PILOT AIR INLET HOLE
We recommend that you clean the unit every
2,500 hours of operation or every three months.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store, or
home center may carry compressed air in a
can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can, you
could damage the pilot assembly.
1/2 GLASS HEIGHT
1.
2.
3.
Yellow
Tipping
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
1/2 GLASS HEIGHT
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 21). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.
Figure 21 - Pilot Inlet Air Hole
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
Exterior
• Use a soft cloth dampened with a mild
12
Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
Inspect burner, pilot for dust and dirt.
Blow air through the ports/slots and
holes in the burner.
Pilot Air Inlet Hole
Pilot Assembly
to clean.
soap and water mixture. Wipe the cabi-
net to remove dust.
104267

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comfort glow cgn10tla

Table of Contents