INSTALLATION
Continued
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 15,
page 14).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of heater is in the OFF
position.
4. Check all joints from equipment shutoff valve
to control valve (see Figures 16 and 17). Apply
noncorrosive leak detection fluid to all joints.
Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 16)
depending on your model). Check all other
internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Ap-
pliance, page 18 or 20, depending on your
model).
Equipment
Gas Control
Shutoff Valve
Valve Location
Figure 16 - Checking Gas Joints
(Propane/LP only)
Figure 17 - Checking Gas Joints (Natural
Gas Only)
111347-01E
Propane/LP
Supply Tank
www.desatech.com