Desa BLUE-FLAME A Operation And Installation Manual page 21

Blue-flame vent-free natural gas heater 18,000 btu/hr non-thermostat, 18,000 btu/hr thermostat, and 28,000 btu/hr thermostat “a” model heaters
Table of Contents

Advertisement

OPERATING
HEATER
Non-Thermostat
Model
Continued
099569
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow "B" in the safety information
at the top of page 20. If you don't smell gas, go to the next step.
5. Press in control knob and turn counterclockwise
position. Keep control knob pressed in for five (5) seconds (see Figure 18).
Note:
You may be running this heater for the first time after hooking up
to gas supply. If so, the control knob may need to be pressed in for 30
seconds. This will allow air to bleed from the gas system.
• If control knob does not pop up when released, contact a qualified
service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This
will light pilot. The pilot is attached to the front of burner. The pilot can be
seen through the glass panel. If needed, keep pressing ignitor button until
pilot lights.
Note:
If pilot does not light, refer to Troubleshooting, pages 24 through 27.
Also contact a qualified service person or gas supplier for repairs. Until
repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure, page 22.
Thermocouple
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
8. Turn control knob counterclockwise
main burner should light. Set control knob to any heat level between HIGH
and LOW. To turn control knob from LOW to a higher setting, press in the
control knob and turn counterclockwise
Note:
Both HIGH and LOW are locked positions. You must press in control
knob before turning it from these positions.
Do not try to adjust heating levels by using the manual shutoff valve.
Ignitor Electrode
Figure 19 - Pilot
to the LOW position. The
C-clockwise
.
C-clockwise
CAUTION
WARNING ICON
G 001
to the PILOT
C-clockwise
Pilot Burner
Continued
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blue-flame

Table of Contents