7.2

Thermal Dissipation

Level
Load
Switch off or remote power off by software*
Power on, amplifier in idle mode
Pink Noise
8Ω / Stereo
(1/8 rated
16Ω / bridged
power)
4Ω / stereo
8Ω / bridged
2Ω / stereo
4Ω / bridged
Pink Noise
8Ω / Stereo
(1/4 rated
16Ω / bridged
power)
4Ω / stereo
8Ω / bridged
2Ω / stereo
4Ω / bridged
*Power absorbsion with amplifier switched off is not zero because to comply with EN60065/IEC 60065:2001-
12 all amplifier circuitry must include a "bleed" resistor across the incoming AC mains power to discharge
residual current to prevent the risk of shock from an amplifier disconnected from the mains.
All material © 2010 Martin Audio Ltd. Subject to change without notice
Martin Audio MA12K & MA12KDSP
Rated
AC Mains
Power
230V AC
115V AC
0.86
0.52
0.8
Watt
Ampere
2 x 2000
3.4
6.8
1 x 4000
2 x 4000
6.1
12.2
1 x 8000
2 x 6000
8.8
17.6
1 x 12000
2 x 2000
5.9
11.9
1 x 4000
2 x 4000
11.3
22.6
1 x 8000
2 x 6000
16.8
33.5
1 x 12000
Watt
Out
In
0
2.95
1.6
0
160
Watt
500
625
1000
1250
1500
1875
1000
1250
2000
2500
3000
3750
Thermal Dissipation
Dissipated
BTU/hr
Kcal/hr
2.95
10
2.5
160
546
138
BTU/hr
Kcal/hr
285
847
214
410
1244
314
535
1668
421
410
1147
290
660
1943
491
910
2791
705
39