External Control Device Setup
Use this function to specify a Monitor ID number.
Refer to 'Real Data Mapping 1'. See page 35.
1. Press the MENU button and then use _, /_" button to select the SPECIAL menu.
2. Press the _ button and then use _, / _" button to select Set ID.
3. Press the I_ button and then use 4 / _. button to adjust
Set ID to choose the
desired Monitor ID number. The adjustment
range of Set ID is 1 - 99.
4. Press the ENTER button to save.
Communication
Parameters
. Baud rate : 9600 bps (UART)
. Data length : 8 bits
. Parity : None
* Use a crossed (reverse) cable.
. Stop bit : 1 bit
. Communication
code : ASCII code
Command
Reference List
COMMAND 1 COMMAND 2
DATA
(Hexadecimal)
01. Power
k
a
0- 1
02. Input Select
k
b
2 _ 9
03. Aspect Ratio
k
c
1 _ 4
04. Screen Mute
k
d
0 _ 1
05. Volume Mute
k
e
0 _ 1
06. Volume Control
k
f
0 - 64
07. Contrast
k
g
0 _ 64
_htness
k
h
0 _ 64
09. Color
k
i
0 _ 64
10. Rnt (option)
k
j
0 _ 64
11. Sharpness
k
k
0 - 64
12. OSD Select
k
I
0 _ 1
13. Remote control lock mode
k
m
0 _ 1
_lit
Zoom
k
p_
0 _ 99
15. Treble
k
r
0 _ 64
16. Bass
k
s
0 - 64
17. Balance
k
t
0 _ 64
18. Color Tern erature ACC
k
u
0 _ 3
19. Red Adiustment
k
v
0 _ 50
20. Green Adjustment
k
w
0 _ 50
21. Blue Adjustment
k
$
0 - 50
22. Abnormal Status
k
z
0 _ a
23. ISM Method
j
p
1 _ 8
24. Low Power
i
q
0 _ 1
25. Orbiter Rme Setting
j
r
1 _ FE
26. Orbiter Pixel Setting
j
s
1 - 3
27. Auto Configure
j
u
1
28. Key
m
c
Key Code
29. Input select (Main)
x
b
Refer to p.38
* When setting the 22 _ 27, a menu doesn't display on screen.
Transmission
/ Receiving
Protocol
Transmission
[_
][Set ID][ ][Data][Cr]
* [Command
1]
First command to control PDP set.
(j, korm)
* [Command
2]
Second command to control PDP set.
* [Set ID]
You can adjust the set ID to choose
desired monitor ID number in special
menu.
Adjustment
range is 1 _ 99.
When selecting
Set ID '0', every
connected
PDP set is controlled.
Set ID is indicated as decimal (1-99) on
menu and as Hexa decimal (OxO-Ox63)
on transmission/receiving
protocol.
* [DATA]
To transmit command data.
Transmit 'FF' data to read status of
command.
* [Cr]
Carriage Return
ASCII code 'OxOD'
* [ ]
ASCII code 'space (Ox20)'
OK Acknowledgement
__Command2][
][Set ID][ ][OK][Data][x]
i
* The Monitor transmits ACK (acknowledgement)
based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
Error Acknowledgement
_Command2][
][Set IU][ ][Ne][Uata][x]
i
* The Monitor transmits ACK (acknowledgement)
based on
this format when receiving abnormal data from
non-viable functions or communication
errors.
Data 1: Illegal Code
2: not support function
3: Wait more time
34