MPX 1 V1.10 MIDI Implementation Details
03

Parameter Type Message

This message is transmitted from the system in response to a request for Parameter Type at a specific
Control Address. This allows external equipment to build a control tree of the system by requesting the
parameter at an address, checking its description to identify it as a Control Level or an adjustable
parameter. (Control Levels indicate at least one lower level.)
Transmit only
Byte # Value HEX
1
F0
2
06
3
09
4
0bbb bbbb
5
03
6-9
0n
10
F7
Control Levels are used in the request message for this packet as follows:
0n
Number of Control Levels
0n
Number of Control Levels
0n
Number of Control Levels
0n
Number of Control Levels
0n
Control Level A
0n
Control Level A
0n
Control Level A
0n
Control Level A
0n
Control Level B
0n
Control Level B
0n
Control Level B
0n
Control Level B
To request the Parameter Type number for Program - EQ - 1 Band (M) - Gain ) on a system with the Device
ID set for 0, send:
——header——
F0 06 09 00 06
Level B
(EQ)
02 00 00 00
14
Description
Sysex ID (Start)
Lexicon ID
MPX 1 ID
Device ID
Message Class
Parameter Type (2 bytes)
End of Sysex
(lo nib)
(lo mid nib)
(hi mid nib)
(hi nib)
(lo nib)
(lo mid nib)
(hi mid nib)
(hi nib)
(lo nib)
(lo mid nib)
(hi mid nib)
(hi nib)
request
Num Control
class
levels
03 00
04 00 00 00
Level C
Level D
(1 Band (M))
(Gain)
01 00 00 00 02 00 00 00 F7
Notes
0-127
Parameter Type
0x0000-0x01BF (see list)
(Nibble 1 of argument)
(Nibble 2 of argument)
(Nibble 3 of argument)
(Nibble 4 of argument)
(Nibble 5 of argument)
(Nibble 6 of argument)
(Nibble 7 of argument)
(Nibble 8 of argument)
(Nibble 9 of argument)
(Nibble 10 of argument)
(Nibble 11 of argument)
(Nibble 12 of argument)
Level A
(Program)
00 00 00 00
Lexicon