Replacing System Fan

The system fan is located on the back of the Intel
Note: Replacement of the system fan should only be done by qualified service personnel.
Note: Before performing any maintenance on the storage system, back up all data. Shut down
the storage system by selecting the Advanced tab from the Manager and then Shutdown
from the left menu.
1. Observe all safety and ESD precautions listed in
2. Remove the new system fan from its packaging.
3. If you cannot shut down the system using the software Manager then power down the
storage system by pressing and holding the power button for approximately five
seconds until the System Status LED starts flashing. The storage system shuts off after
a short shutdown period.
Caution: Ensure the system is completely shutdown before removing the power chord.
4. Disconnect the storage system from its power source.
5. Remove the four screws at the back of the enclosure cover. See letter "A" in the
following figure. Slide the enclosure cover slightly rearward and then lift up. See
letter "B".
A
A
®
Intel
Entry Storage System SS4000-E User Guide
A
A
K

Figure 30. Removing Enclosure Cover