Denon DN-V1700 Operating Instructions Manual page 31

Network audio video player
Hide thumbs Also See for DN-V1700:
Table of Contents

Advertisement

Available languages

Available languages

2 Label format
• Label lines may consist of any character strings of up to 8 characters beginning with a sharp ("#") (maximum 9 characters
including the "#").
• The sharp is omitted when specified as such parameters as "GOTO", "ONKEYGO", or "ONBREAK".
• The characters that can be used in label names are capital letters "A to Z", small letters "a to z" and numbers "0 to 9".
2 Parallel remote terminal
During script playback, parallel remote terminal pins 1 to 6, 11 and 12 function as keys 1 to 8, and can be used with the script
command "ONKEYGO", for example.
2 List of script commands
("n" refers to an integer)
Command
@
01
comment
02
play
03
play standby
04
play start
05
end
06
pause
07
still
08
stop
09
audio control
@
10
video control
@
11
goto
12
vitc set
@
13
wait
14
on key goto
@
15
on SMPTE-tc goto
@
16
if day of week goto
@
17
on rtc goto
@
18
on break goto
@
19
osd display
@
20
osd print
@
21
osd attribute
@
22
osd clear
@
23
tc interrupt control
@
24
rtc interrupt control
@
25
com-port set
@
26
com-port put
@
27
parallel out set
@
28
drive change
29
site command enable
@
30
SNTP time calibration
31
still mode set
@
32
variable set
@
33
loop
34
write log file
"@" in the "@" column indicates commands for which "@" can be used.
Format
;
Comment
Playback of 1 or 2 files. The script does not move to the next step unless the file is
PLAY
played to the file end
PLAYRDY
Preparation for file playback
PLAYGO
Start playback of file for which the play standby mode is set from the specified TC
END
End/change script file execution
PAUSE
Set pause mode (screen blacked out)
STILL
Set pause mode (still picture displayed on screen)
STOP
Stop playback (still picture displayed on screen)
AUDIO
Switch audio output on and off
VIDEO
Switch video output on and off
GOTO
Forced change of command sequence
SETTC
Set SMPTE time code
WAIT
Wait specified number of seconds or until specified time code
ONKEYGO
Set a forced change of command sequence at the time of key input
ONSMPTCGO
SMPTE timer interruption
IFDWKGO
Change command sequence according to day of week
ONRTCGO
Real time timer interruption
ONBREAK
Specify new processing position when an execution break command is received
OSDDISP
Switch user OSD display on and off
OSDPRT
Write 1 line of user OSD
OSDATT
Set user OSD attribute
OSDCLR
Clear line(s) of user OSD
TCINT
Disable/enable time code interruption
RTCINT
Disable/enable RTC interruption
COMSET
Serial port communications mode setting
COMPUT
Output 1 line from serial port
OUTPORT
Parallel remote output terminal setting
DRV
Change current drive
SITECMD
Enable acceptance of site command
TIMECAL
Time calibration by SNTP server
STLMODE
Set screen display in still mode
SET
Set loop counter value
LOOP
Loop according to loop counter and label
WRITELOG
Output log to file
Description
ENGLISH
31

Advertisement

Table of Contents
loading

Table of Contents