A
S
UDIO
COPE AND
The RX waveform can be observed on Voice and CW modes, also the TX Voice waveform can be observed, allowing
optimal adjustment of setup options or filter settings.
1. Press the [ F6 ]( LEVEL ) key to set the level as ap-
propriate for the signal strength being monitored.
Available values are:
0.3 V 0.1 V 1.0 V 0.3 V ......
2. Press the [ F7 ]( SWEEP ) key to set the desired
sweep time. Available values are:
10 ms 30 ms 100 ms
Advice: When monitor the TX waveform, turn on the
monitor feature by pressing the front panels [ MONI ]
key.
Frequency Range: 0 - 4 kHz
Sweep Speed: 10/30/100/300/1000ms (adjustable)
Time Base Indication: One frame: 10 divisions (20 gradations) "Sweep time / 20"
Signal Processing: AC Level Detection Synchronizer function
Input Level: 1 Vp-p Input (ADC Max. value)