PROBLEM
POSSIBLE
CAUSE(S)
CORRECTIVE
ACTION
DRIP FROM
RELIEF
VALVE
1.
Excessive
water
pressure
1.
Use a pressure
reducing
valve
and relief
valve
2.
Closed
water
system
2.
See "Thermal
Expansion"
THERMOSTAT
FAILS TO
1.
Non-functioning
thermostat
1.
Replace
thermostat
SHUT OFF
2.
Improper
calibration
2.
Replace
thermostat
COMBUSTION
ODORS
1.
Insufficient
air
1.
Provide
ventilation
to water
heater.
Check
flue
way, flue baffle,
and burner
2.
Water
heater flue or vent system
blocked.
2.
Clean,
locate
source
and correct
3.
Heater
installed
in a confined
area
3.
Provide
fresh
air ventilation
1.
Flammable
vapor
incident
1.
Call 1-800-4-MY-HOME
_'(1-800-469-4663)
SMOKING
AND CARBON
FORMATION
(SOOTING)
CONDENSATION
BURNER
FLAME
FLOATS
AND LIFTS
OFF PORTS
1.
Temperature
setting
too low
1.
Orifice
too large
2.
High gas pressure
3.
Water
heater flue or vent system
blocked.
4.
Cold drafts
5.
Dirty burner screen
1.
Increase
the temperature
setting
1.
Replace
with correct
orifice
2.
Check
with gas utility company
3.
Clean flue and burner-locate
source
and
correct
4.
Locate
source
and correct
5.
Clean burner
screen.
See "Ultra
Low
NOx Natural
Gas Burner"
section
of this
manual.
FLAME
BURNS
AT ORIFICE
1.
Non-functioning
thermostat
1.
Replace
thermostat
2.
Low gas pressure
2.
Check
with gas utility company
3.
Non-functioning
burner
3.
Replace
burner
assembly
PILOT
FLAME
TOO SMALL
1.
Pilot line or orifice
clogged
1.
Clean,
locate
source
and correct
2.
Low gas pressure
2.
Check
with gas utility company
3.
Dirty pilot
3.
Clean
pilot
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power miser 12153.331242153.331252

Table of Contents