Kenmore 32607 - 20 Gallon Tall Compact Electric Water Heater Owner's Manual page 5

Compact electric water heater
Table of Contents

Advertisement

HEATER R EQUIRES
ABILITY E QUIVALENT
TOTHAT OF
A LICENSED TRADESMAN
INTHEFIELD INVOLVED.
PLUMBING
AND ELECTRICAL
WORK A RE REQUIRED.
Examine
the location toensure the water heater complies with the
"Facts toConsider About theLocation"
section inthis manual.
5. ForCalifornia installation this water h eater must b ebraced,
anchored, or strapped t o avoid fallingor moving during
an earthquake. Seeinstructions for correct i nstallation
procedures. Instructions may beobtained f rom California
Office oftheState Architect, 400PStreet, S acramento,
CA95814.
6. Massachusetts Coderequires thiswaterheater t o be
installed in accordance withMassachusetts 248-CMR
2.00:State Plumbing Code and248-CMR 5 .00.
MODEL
NUMBER
153.316040
153.316050
153.316060
153.316070
153.316331
153.326060
153.326070
153.326331
TANK
CAPACITY
IN GALLONS
(LITERS)
6 (22.7)
I0 (37.8)
I9 (71.9)
19.9 (75.3)
30 (113.6)
I9 (71.9)
19.9 (75.3)
30(113.6)
DIMENSIONS
IN iNCHES (ram)
DIA.
HEIGHT
14.250_'/362/15.375"/391
/
16"(406)
18.25"(464)
18"(457)
24.9"!632)
16"(406)
31.62"(803)
22"/559 )
30"(762)
18"(457)
24.9"(632)
16"(406)
31.62"(803)
22"(559)
30"(762)
ELEMENT
RECOVERY
RATE
WATTAGE
GALS.PER
HOUR
,_90°F Rise
120 Volt
240 Volt
7.5
I650
....
7.5
I650
....
7.5
I650
....
7.5
I650
....
7.5
I650
....
9.1
....
2000
9.1
....
2000
9.1
....
2000
MiNiMUM
WIRE SIZE*
(GAUGE)
I2
I2
I2
I2
I2
I4
I4
I4
MAXIMUM
FUSE
OR CiRCUiT
BREAKER
SIZE (AMPS)
20
20
20
20
20
I5
I5
I5
* Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.
Explosion
Hazard
. Models with optional Top Hot Outlet
or T&P
location are identified
as
EITHER Hot Outlet or T&P.
. Models
with
optional
installation
locations on jacket top can NOT be
installed with both Hot Outlet and
T&P located on top.
- Never attempt to use Cold inlet on
jacket top as Hot Outlet or T&P.
* Connections
should
only be used
as identified on heater.
Failure to
use them properly could result in
damage to the water heater, serious
bodily injury, or death.
Some
compact
models
have labeled
optional
plumbing
connections
see below.
MODEL
STANDARD
STANDARD
STANDARD
MODEL HAS OPTIONAL
MODEL HAS OPTIONAL
NUMBER
SiDE COLD iNLET
SiDE HOT INLET
SIDE T&P
TOP COLD INLET
TOP HOT OUTLET OR T&P
I53.316040
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
I53.316050
YES
YES
YES
NO
YES, PLUGGED
I53.316060
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
I53.316070
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
I53.316331
YES
YES
YES
NO
NO
I53.326060
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
I53.326070
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
I53.326331
YES
YES
YES
NO
NO

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents