User Action: If the board status is generalFailure(3), you may need to replace the controller. If the
board status is cableProblem(4), check the cable connections between the controller and the storage
system.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaCntlrHwLocation
•
cpqDaCntlrIndex
•
cpqDaCntlrBoardStatus
•
cpqDaCntlrModel
•
cpqDaCntlrSerialNumber
•
cpqDaCntlrFWRev
•
cpqDaAccelTotalMemory
Supporting SNMP Trap Description: "Status is now [cpqDaCntlrBoardStatus]."
Event Identifiers 1200- 1 294
NT Event ID: 1200 (Hex)0x843504b0 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Logical Drive Status Change.
Log Message: Logical drive number %5 on the array controller in %4 has a new status of %2.
SNMP Trap: cpqDa6LogDrvStatusChange - 3034 in CPQIDA.MIB
Symptom: Logical Drive Status Change. This trap indicates that the agent has detected a change in
the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical
drive status.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaCntlrHwLocation
•
cpqDaLogDrvCntlrIndex
•
cpqDaLogDrvIndex
•
cpqDaLogDrvStatus
Supporting SNMP Trap Description: "Status is now [cpqDaLogDrvStatus]."
NT Event ID: 1201 (Hex)0x843504b1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, port %5, bay %6 has a new status of %2.
SNMP Trap: cpqDa6SpareStatusChange - 3035 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the
status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive
status.