Factory Default Settings - Danby Premiere DDR7009REE Owner's Use And Care Manual

Portable dehumidifier
Table of Contents

Advertisement

Available languages

Available languages

1) Place the product in an upright position on a flat, stable, and heat-resistant
START
surface. Make sure there is nothing flammable or heat sensitive within 100cm
OPERATION
(39 inches). Operating the product in any other position could cause a hazard.
2) Insert the plug into a suitable wall socket (Fig. 1) The
dehumidifier is suitable for operating on an electricity supply having
the same voltage as that shown on its rating label.
3) Make sure the water tank is correctly located. After switching on
the machine for the first time, if the "Bucket Full" light illuminates,
pull out the water tank, and check that the "float" lever is able to
move freely, then return the water tank to the correct position (Fig.2).
WATER FULL
When the water tank is full and/or incorrectly positioned inside the cabinet, the water
INDICATOR
full red light turns on and remains on until such time that the tank is emptied and/or
LIGHT(RED)
correctly re-positioned.
This condition will result in the immediate shut down of the dehumidifying system (both compressor and fan
motor operations are terminated). This is a safety feature. When the water tank is emptied and/or correctly
re-positioned, the dehumidifier will resume operation automatically.
NOTE: It may take several minutes before operating conditions resume.
BUCKET FULL
When the water tank is full the machine will stop and the
LIGHT ON
"Bucket Full" light will illuminate.
The water tank should be carefully removed from the machine by sliding it
outward from the front of the unit, and it should be emptied. When the empty
tank is replaced properly in the machine, the unit will start up and run normally
(Fig. 3).
FACTORY
DEFAULT SETTING
Each time the unit is disconnected/re-connected and/or in the event of a power failure, the electronic circuit
board automatically defaults to the following factory setting:
Humidity Setting: 60%
NOTE: In the event of a power failure, all previous settings are automatically erased/cancelled. If your
program setting was different from the above (default setting) it will be necessary to re-program your settings.
When the unit is switched "Off" manually (using the on/off keypad) the unit will always default to the last
program setting that was used.
Proper installation of the water tank is crucial in maintaining reliable dehumidifier
WATER TANK
operation. The water tank holds accumulated condensed water and, by means of a safety
OPERATION
switch, controls both the water level and operation of the dehumidification process.
When the water tank is full and/or accidentally displaced insider the cabinet, the float switch actuator (inside
the tank) breaks contact with the safety swtich. This condition results in the immediate shut down of the
compressor and fan motor system, preventing moisture from being condensed.
NOTE: Never tamper with or attempt to defeat the water level (safety) float switch system.
OPERATING INSTRUCTIONS (cont'd)
Fan Speed: Low
Fig. 2
8
Fig. 1
Fig. 3
Please use
both hands
to carefully
empty the
water tank.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premiere ddr5009reePremiere ddr6009reePremiere

Table of Contents