6 Installation Steps; Vent Connection; Gas Connection - Whirlpool SC8720EDB - GAS DOWNDRAFT Installation Instructions Manual

30" gas downdraft cooktop
Hide thumbs Also See for SC8720EDB - GAS DOWNDRAFT:
Table of Contents

Advertisement

Installation steps
Preparation
A
WARNING
Excessive Weight Hazard
Use two or more people to move and
install cooktop.
Failure to do so can result in back or
other injury.
1.
Remove the downdraft cooktop
from packaging.
2.
Check equivalent vent length to
determine if blower should be set at
"Low" or "High" range (see chart on page
4 to determine equivalent vent system
length). If vent system length is greater
than 30 feet (9.1m), shift the blower range
setting from "Low" to "High" (see
instructions on page 4 for shifting the
blower range).
If blower must be shifted to "High" range,
do it now.

Gas connection

D
IMPORTANT: All connections must be
wrench-tightened. Do Not make
connections to the gas regulator too tight.
Making the connection too tight may crack
the regulator and cause a gas leak. Do Not
allow the regulator to turn on the pipe when
tightening fittings.
Page 5
B
Align cooktop
in cutout
A
Blower range
setting
Installation
B
3.
Insert downdraft cooktop into
cutout. Check that:
cooktop is centered in cutout.
front edge of downdraft cooktop is at
least 1-1/2" (3.8 cm) from front edge of
countertop and parallel to countertop.
side edge of cooktop is at least 2 inches
(5.1 cm) from side wall.
All connections must be wrench-tightened.
5.
Assemble
the flexible connector
1/2"
nipple
from the gas supply pipe
to the pressure regulator
in order: manual shutoff
valve, 1/2" nipple,
flexible
connector
1/2" adapter, flexible
connector, 1/2" adapter,
1/2" nipple and pressure
regulator. Or install rigid
1/2"
piping as required.
nipple
6.
Use pipe-joint compound made for
use with L.P. gas to seal all pipe thread gas
connections. If flexible connectors are used, be
certain connectors are not kinked.
C
Vent system
connection
C
4.
"Venting requirements," pages 3-4. Use
duct tape to seal all joints. Vent must end
with a wall or roof cap outside the
building.
burner box
to downdraft
pressure
cooktop
regulator
7.
1/2"
adapters
the gas supply line. Wait a few minutes for
the gas to move through the line.
manual
8.
shutoff
valve
test all gas connections. Bubbles around the
connections will indicate a leak. If a leak
appears, shut off gas valve controls and
adjust connections. Then check connections
again. NEVER TEST FOR GAS LEAKS WITH
A MATCH OR OTHER FLAME. Clean all
detergent from the cooktop.
Note: Cooktop shown
with optional grill
accessory.
E
Check each burner
for proper flame
D
Gas supply
connection

Vent connection

Connect vent system. See
shutoff valve
"open" position
to gas
supply
Open the manual shutoff valve in
Use a brush and liquid detergent to

Hide quick links:

Advertisement

Table of Contents
loading